12
Jetter AG
1 Safety instructions
Instructions on EMI
To satisfy EMC requirements, connect the CAN cable shield to the module
housing. Connection of pin 16 (shield) alone is insufficient for effective
shielding.
Connect the shielding of the CAN cable to the threaded pin of the module
housing:
Number
Part
1
Threaded pin of the module housing
2
Washer
3
Cable lug
4
Lock washer
5
Screw nut
To satisfy EMC requirements, connect the video cable shield to the module
housing. The ground connections (pin 4 and pin 7) are insufficient for effective
shielding.
Connect the video cable shield to the threaded pins of the module housing:
Wiring instructions -
CAN cable
Wiring instructions -
Video cable