Jetter AG
Technical specifications | 4
JVM-206-K00-O21 User Manual
13 / 32
4.10 Inputs/outputs according to ISO11786:1995
Within the operating voltage range, all inputs are voltage-proof and overcurrent
protected.
Digital inputs for
tractor speed
Category
Description
ISO11786 - Digital inputs for wheel speed and ground speed with two modes
Abbreviation
IN_1 … IN_2
Quantity
2
Pull resistor
4.7 KOhm
H level
Mode 1: ≥ 3.4 V
Mode 2: ≥ 6.2 V
L level
Mode 1: ≥ 2.5 V
Mode 2: ≥ 1.5 V
Accuracy
2 %
System menu functions
Mode and pull-up selec-
tion
Pulse/meter Calibration
Tab. 12:
Digital tractor speed inputs according to ISO11786:1995
PTO speed input
Category
Description
ISO11786 - PTO speed
Abbreviation
PTO_IN
Quantity
1
Pull resistor
4.7 KOhm
Can be disabled
H level
Mode 1: ≥ 3.4 V
Mode 2: ≥ 6.2 V
Default = Mode 1
L level
Mode 1: ≥ 2.5 V
Mode 2: ≥ 1.5 V
Signal
Up to 20%/80% duty cy-
cle
Tab. 13:
PTO speed according to ISO11786:1995
Hitch position (digi-
tal input)
Category
Description
ISO11786 - Hitch position (digital input)
Abbreviation
TP_DI_IN
Quantity
1
H level
≥ 6.2 V
L level
≥ 1.5 V
Source resistance
100 Ohm ± 10 Ohm
Input resistance
> 3 kOhm
Tab. 14:
Hitch position - digital input according to ISO11786:1995