Jetter AG
Register overview - Multi-purpose inputs and outputs | 9
JVM-104-O09 User Manual
54 / 62
Register
Description
6010x0001
Commands, bit-coded
Bit 7 … 4
0000 =
Frequency measurement using gate time
0011 =
Counting mode
0100 =
Period time measuring, 10 s timeout
0101 =
Period time measuring, 1 s timeout
0110 =
Period time measuring, 100 ms timeout
Bit 9
0 =
Voltage measuring
1 =
Current measurement
Bit 12
0 =
Activate pull-up resistor
1 =
Deactivate pull-up resistor
6010x0002
Analog value in mA/µA
6010x0003
Frequency [gate time]/period [μs]/count value [increments]
6010x0004
Digital value at the input
6010x0005
Gate time in ms within frequency metering
9.3 Multi-purpose outputs PA1 ... PA4
Placeholders are used for these register numbers. If, for example, two similar
functions are shifted by an offset, searching becomes easier. The following rule
applies:
x = 3 for multi-purpose output 1 (as of 601030000)
x = 4 for multi-purpose output 2 (as of 601040000)
x = 5 for multi-purpose output 3 (as of 601050000)
x = 6 for multi-purpose output 4 (as of 601060000)
Register
Description
6010x0000
Status
Bit 0
Overcurrent of H-side
1 =
Overcurrent detection has tripped
Bit 3
Overcurrent of L-side
1 =
Overcurrent detection has tripped
Bit 6
Cable breakage (open load)
1 =
A cable breakage is present
Bit 7
Overtemperature
1 =
Overtemperature is present
Bit 14
Multi-purpose output is ...
0 =
enabled
1 =
disabled
Bit 15
Hardware protection has tripped
1 =
Hardware protection has tripped due to overcurrent/
short circuit
6010x0001
Commands, bit-coded
Bit 1 … 0
00 =
Output PAx as digital output
01 =
Output PAx as PWM output
Bit 3 … 2
00 =
Output PAx as input
01 =
Output PAx as low-side output
10 =
Output PAx as high-side output
11 =
Output PAx as low-side output