Operating Parameters
Mechanical Parameters
Parameter(s)
Value(s)
Reference
standard
Free falls
withstanding test
Within original packing, the device
withstands dropping over all of its
edges
DIN EN 50178
DIN EN 60068-2-31
Vibration resistance
• 10 Hz ... 57 Hz : 0.075 mm
amplitude
• 57 Hz ... 150 Hz: 1.0 g
constant acceleration
• 1 octave per minute, 10
frequency sweeps (sinusoidal),
all three spatial axes
DIN EN 50178
DIN EN 60068-2-6
Class of protection
IP 20
DIN EN 60529
Mounting position
Vertical
Please make sure there is a
clearance of at least 100 mm
under and above the module -
sufficient ventilation must be
granted.
NOTICE
Measures to avoid damages in transit and storage:
The packaging material and the storage place are to be chosen in a
way that the values given in the above table “Operating Parameters
Mechanical Parameters" on page 31 are kept to.
Operating Parameters
Electrical Safety
Parameter(s)
Value(s)
Reference
standard
Protection class
I
DIN EN 61800-5-1
Dielectric strength
Protective network conductor and
network logics: 1.7 kV, 5 s
DIN EN 61800-5-1
Insulation
Protective network conductor and
network logics: > 1 M
at 500 V
DIN EN 61800-5-1
Protective earth
connection
12 V, 10 A, 0.1
DIN EN 61800-5-1
Overvoltage category
III
DIN EN 61800-5-1
DIN EN 50178
DIN VDE 0110-1
UL 508C
Ω
Ω
Summary of Contents for JetMove D203
Page 1: ...User Manual JM D203 230 Digital Servoamplifier 60870727 We automate your success...
Page 10: ...Table of Contents 10 Jetter AG...
Page 36: ...4 Physical Dimensions 36 Jetter AG...
Page 46: ...5 Technical Data 46 Jetter AG...
Page 92: ...11 Option S1 STO 92 Jetter AG...
Page 133: ...JetMove D203 Appendix Jetter AG 133 Appendices...
Page 134: ...Appendices 134 Jetter AG...