JetMove 225-480
5.1 Electrical Specifications
Jetter AG
39
Digital inputs
– Enable (E),
– Reference switch (R);
– Limit switch RH (L+), and
– Limit switch LH (L+);
– Input (Inp)
DC 20 V ... 30 V related to the ground
potential of voltage supply of processor
logics, with an input current of 7.5 mA max.
each.
See "Digital Inputs, Logic Power Supply"
on page 71.
Braking relay
V
max
= DC 30 V
I
max
= DC 2 A
Contact: Type NO
connected to BR1 and BR2 on X10
The lines may only be connected to
devices that are related to the same
potential as the power supply of the
controller logic.
Can be switched by the control program of
PLC or by operating system of JetMove
225-480 together with software enable.
Digital outputs
Number of outputs
Output type
Rated voltage
Voltage range
Load current
Electrical isolation
Protective circuits
Protection against inductive loads
Signal voltage ON
4
Transistor pnp type
24 V
20 ... 30 V related to the ground potential of
voltage supply of processor logics
max. 0.5 A / output
none
Short-circuit, overload, overvoltage,
overtemperature protection
Yes
Type V
supply
- 1.5 V
Power dissipation P
v
Output stage: 250 W max.
Logic circuit: 20 W max.
Electrical Specifications
Summary of Contents for JetMove 225-480
Page 1: ...JetMove 225 480 Digital Servo Amplifier 60874967...
Page 24: ...1 Safety Instructions JetWeb 24 Jetter AG...
Page 36: ...4 Mounting Dimensions JetWeb 36 Jetter AG...
Page 44: ...5 Technical Data JetWeb 44 Jetter AG...
Page 76: ...7 Description of Connections JetWeb 76 Jetter AG...
Page 84: ...JetWeb 84 Jetter AG...
Page 88: ...JetWeb 88 Jetter AG...
Page 116: ...15 Ordering Information JetWeb 116 Jetter AG...
Page 117: ...JetMove 225 480 Appendix Jetter AG 117 Appendices...
Page 118: ...Appendices JetWeb 118 Jetter AG...