Error message on part of a subscription
If a subscriber has not received any process data from the assigned publisher
before timeout, the subscriber will generate an error. The subscriber for the
subscription of which the error has been generated, can run either on a
controller or on a network node. The remote network node is a JX3-BN-ETH,
for example.
The error may be caused as follows:
Communication with the network client providing the process data is
terminated.
The operating system of the device responds to the error by taking the
following steps:
Step
Description
1
Sets bit 1 in R 250000.
2
Writes the subscription ID to R 250002.
3
Sets flag 2081.
4
Writes value 11103 and the ID to the error buffers.
The error buffer can be accessed via registers 380000 ff. (error history).
5
Writes the GNN of the network node communication with which has been
terminated to R 254001.
6
Writes the IP address of the network node communication with which has
been terminated to R 254002.
7
Writes the port number of the network node communication with which has
been terminated to R 254003.
8
If ...
... then ...
... flag 2080 is set,
... bit 3 is set in R 210004 and
R 200008. The red status LED of
the controller is lit.
By means of NetCopy commands, you can precisely locate the error and fix
the root cause. This works, because GNN, IP address and port number of the
other network node are known.
To acknowledge the error, write command 110 to register 250001.
Detecting the error
Root cause of the error
Response of the device
to this error
Fixing the root cause
Acknowledging the error
Summary of Contents for JC-120MC
Page 1: ...User Manual JC 120MC Controller 60880901 We automate your success...
Page 18: ......
Page 40: ...40 Jetter AG 3 Identifying Hardware revisions see page 38 Related topics...
Page 160: ......
Page 186: ......
Page 196: ......
Page 485: ...Jetter AG 485 JC 120MC Programming Topic Page Programming 486 Registers 498 Contents...
Page 521: ...Jetter AG 521 JC 120MC Programming Use 29 bit identifier Default 11 bit identifier...
Page 586: ......
Page 604: ......
Page 633: ......