OPERATION
This section describes the operation of the
TwinForce™ Series unit.
Preparing the Unit
1. Remove All Shipping Protection
2. (For trailer and skid units) The exhaust
stack rain cap (Figure 30) will be tie-
wrapped shut for transport. Remove the
tie wrap and tags from the engine ex-
haust stack.
3. Remove all on board packages.
4. Inspect the unit and report any damage to
your Jetstream representative.
5. Remove the pump wrench from the rod
!
!
CAUTION
When mounting skid units on a trailer or truck,
orient the rain cap so the flapper on the exhaust
stack opens to the rear. If not oriented properly it
will allow rain to enter the exhaust when traveling
and the turbo will be damaged from spinning
backwards without lubrication.
ATTENTION
Figure 30: Typical Exhaust Stack.
Tags
Pump
Wrench
Figure 31: Pump Wrench Removal.
For shipping and safety concerns, the unit is
transported with very little fuel or no fuel. Add fuel to
the fuel tank before starting the unit.