background image

Jets™ Jade Floor Toilet 

Tel. +47 70 03 91 00

www.jetsgroup.com

Product No. TO661PO

Rev 2017-08-29 14:46

5

General Installation Information

Note:  To avoid leakage between the toilet valve and the toilet bowl, it is important that the pipe is correctly aligned.  Connections are to be secured 
with hose clamps.

Installation

General Disclaimer

Drawings provided in the following examples are for illustration purposes only. Product details may vary from your individual purchase. 

Installation Instructions

Toilet installation requires the following procedures to be carried out. For more specific technical details, refer to the individual data sheet. For 
further information on any of the instructions supplied, any questions regarding installation or the products, please contact your local supplier or 
Jets™ Service Department. 

1

For installations with a pre-installed 
valve, go to step 3.

2

Install the toilet valve 

and the 

spring 

as per the products 

installation instructions found in 
the products data sheet.

3

If using Installation Alternative 2, affix 
the cap (A) from the Pipe Cover 

to 

the wall. (B) will be installed later.

4

Move the toilet close to the wall.

Connect the ball valve from the 
toilet valve to the water main.
Note: Do not over tighten.

5

Connect the release button/mechanism to the toilet valve.
For connection information see the installation description provided in the 
Release Button's technical data sheet.

6

Press the valve onto the pipe 
connection securely.

Note:  Refer to Toilet 
Connections - Installation 
Alternative 1 and Alternative 2.

7

Adjust the length and install the Pipe 
Cover (B) between the toilet bowl 
and the wall to cover the 
connections.

8

If using Installation Alternative 2, 
use a cutting knife to cut out the 
pipe access hole (A) in the back 
cover 

.

9

Install the back cover to the rear of 
the toilet bowl.

10

Use silicon or similar beneath the 
toilet bowl (A) to secure the bowl 
to the floor.

Make sure you do not block the 
drain opening (B).

Summary of Contents for Jade

Page 1: ...ge Valve Outlet Outside diameter Ø 50 mm Water Connection male BSP Generic Material Porcelain Net Weight N A Coating Vitreous China Operating Data Flushing Time 5 seconds Discharge Time 2 seconds Water Pressure 2 7 bar Operating Vacuum Recommended 30 55 Vacuum Air Consumption Approx 48 liters at 50 Vacuum Water Consumption 1 liter s 3 bar Temperature Range Minimum 1 C to Maximum 60 C unless frost ...

Page 2: ...m C If H is 40mm 115mm D If H is 40mm 160mm E Release mechanism normal height 670mm F 830mm G Release mechanism public toilet height 950mm H see note 40mm I If H is 40mm 155mm J 65mm Note If the toilet is placed further than 40mm away from the back wall the values of C D F and I will change H Should be a minimum of 40mm and a maximum of 70mm ...

Page 3: ...entified lifting points or as instructed in the current IOM Note Lifting devices eyebolts slings spreaders etc must be rated selected and used for the entire load being lifted 1 4 Caution Safety equipment PPE necessary for the prevention of accidents at the installation and operating site must be provided in accordance with local regulations 1 5 Personal Protective Equipment Goggles Wear safety gl...

Page 4: ...onto the wall if mounting requires that the water barrier be compromised Check requirements according to local codes and standards before beginning any installation work Pre Installation Considerations It is recommended that items such as wall mounted release buttons drainage and piping etc is installed prior to installation of the toilet Connection with Mains Water The connection required is a 1 ...

Page 5: ...3 2 Install the toilet valve and the spring as per the products installation instructions found in the products data sheet 3 If using Installation Alternative 2 affix the cap A from the Pipe Cover to the wall B will be installed later 4 Move the toilet close to the wall Connect the ball valve from the toilet valve to the water main Note Do not over tighten 5 Connect the release button mechanism to...

Page 6: ...or a copy of technical information regarding freezing protection measures 5 CAUTION Never use automotive antifreeze ethylene glycol in the toilet system 6 Turn off the power NOTE Failure to adequately protect the toilet system from damages may result in void of your warranty coverage NOTE Jets Vacuum AS reserves the right to deny any warranty claim submitted if the claim is caused by freezing dama...

Page 7: ...quipment and take measures to prevent future damage to the system Note that frost and or freezing may damage sanitary systems if precautions have not been taken Contact your nearest Jets supplier for information on Jets range of frost protection products for installations in cold climate locations Troubleshooting Jets Vacuum AS provides the following troubleshooting information to assist in resolv...

Page 8: ...8 Backflow in the installation Check the pipes have been correctly installed The Non return Valve on the discharge line if installed is malfunctioning Clean the Non return Valve If connected to a tank the tank could be full or the air overflow blocked Check that the air overflow is open Empty the tank ...