IMPORTANT:
Ensure allowance made for firebox to sit on Finished Floor Protector Level
ALL INSTRUCTIONS TO COMPLY WITH AS/NZS2918:2001
IMPORTANT: Read all instructions carefully before starting installation. Failure to follow these instructions
may result in a fire hazard and will void the warranty.
The JeTMAsTeR uNIT Is TO be INsTAlled by A ceRTIfIed fIRePlAce INsTAlleR OR AN APPROved
NZhhA INsTAllATION TechNIcIAN.
See www.homeheat.co.nz/members for a Certified NZHHA SFAIT installer in your area.
The flue system must be cleaned every 12 months.
AleRT: for Outdoor Jetmaster fires into timber framing,
please refer to The Fireplace for recess
allowances and provision for the Stainless Steel Weather Cover.
Fig. 1
Hebel Block
Margin Lintel
Hebel Block
Margin Leg
Floor Protector
min. 75mm thick Hebel Block for wooden floor
(see Table 4 for Floor Protector dimensions)
min. 100mm thickness required for poured
concrete
min. 200mm over
internal opening
Timber Framing
Air Vents required for cavity
ventilation - connect to
outdoor where possible
Lintel Bar where
necessary
Heat Shield
OPTIONAL
Bird proof netting over the top &
down sides. Cut penetration for
flue pipe
Due to continued product improvement, The Fireplace Ltd reserves the right to change product specifications without prior notification
Vents for
Air Replacement
Please check to ensure you have the latest installation instructions
TyPIcAl JeTMAsTeR IN-buIlT TIMbeR fRAMe INsTAllATION INsTRucTIONs
- WOOd -
7/2013
5.TW.1A