MODEL
A
B
Temporary Lintel
C
D
E - Vents
1050
1150
700
1200
100
860
2 x 160dia. or 2 x (100x
200)
Table 3
MASONRY MINIMUM CAVITY SIZE
Fig. 11
PLAN - RECESS DETAIL
min. 25mm clearance
25
25
min. 25mm clearance
700mm
+ recess
Masonry or Hebel block
minimum ‘A’
Refer
to Table
5 f
or Floor Protector dimension
RECESS REQUIRED (40mm Min. 100mm Max)
Allow gas line into
firebox
(if applicable)
Air Vent
‘Refer
to Table
5
for
Floor
Protector dimension
Air Vent
min. 2 x 100 x 50mm or 80mm diam
wall of floor mounted air vents
Dr
awings
Not
To S
cale
9
Note: If the appliance is exposed not under protective cover please recess the appliance
.
Min =40mm/Max recess = 100mm.
Add recess dimension to B dimension in Table 3.
10
0
700mm
+ recess
Allow 5mm gap
around all four
sides of the firebox
to fit Stainless
Steel cover & allow
for firebox
expansion
RECESS
REQUIRED
40mm Min.
-
100mm Max recess
CROSS SECTION
min 2 x 160mm dia. or equal square or rectangle shaped
air vents to be wall mounted