JETI model MT125 Manual Download Page 2

 MT125 & MT300 Sensor EX

   

- 2- 

Sensors  of  the  MT300  Module  can  be  used  for  higher  temperatures  (engine  cylinders,  engine  exhausts 
etc.).  The  sensors  are  adapted  to  this  purpose  and  comprise  a  loop  of  heat  resistant  conductor  in  the 
middle.  Before  tightening  moisten  the  silicon  tube  with  alcohol  or  white  spirit  in  order  to  improve  its 
sliding ability on the cables. Put the measuring object, for instance an engine cylinder, through the loop 
and tighten the loop strongly by means of the silicon tube in order to obtain a tight contact between the 
loop and the measuring object (for instance with cooling fins of an engine cylinder). After evaporation of 
the alcohol the silicon tube will firmly hold the loop tight. In order not to damage the sensor the dia. of 
the loop should not be smaller than 20 mm. 
 

Parameter adjustment of MT-Modules 

Parameter adjustment a data readout is accomplished by the JETIBOX terminal. After connection to the 
MT-Sensor  there  appears  an  identification  of  the  sensor  and  in  the  second  line  the  actually  measured 
temperature data of both sensors. By long pushing down button R (right) a fast deletion of all measured 
parameters can be triggered. Fast deletion is indicated in the first line of the display by an asterix „*“. 
By pushing button D (downward arrow) of the JETIBOX  you will enter the MT-Module menu. 
 

Menu of the MT-Module: 
MT125 MENU: 

ACTUAL VALUE

 – 

select  presentation  of actual measured data by pressing button D 

(down arrow)  

Actual Temp.  A –

 presents the actual temperature of sensor A   

Actual Temp.  B –

 presents the actual temperature of sensor B    

 

MT125  MENU

MIN  /  MAX

  –  push  button  D  (down  arrow)  in  order  to  select  the  recorded  extreme 

values which occured during measurements on both sensors.  

Temp.  A    MIN  /  MAX

  –  represents  the  minimum  and  maximum  temperature  value  which  has  been 

recorded by sensor A during all measurements. 

Temp.  B    MIN  /  MAX

  –  represents  the  minimum  and  maximum  temperature  value  which  has  been 

recorded by sensor B during all measurements. 
 
Records  of  all  extremes  can  be  deleted  in  the  menu 

Setting  -  Erase  Data.

  If  you  don´t  delete  all  data 

records manually, the MT-Module will record the maximum and minimum sensor temperatures whether 
it has been in the meantime disconnected of the voltage supply or not,  i. e. the presented data can concern 
preceding operations. 
 

MT125 MENU: 

Setting

 – by pushing button D (down arrow) the basic MT-Module adjustment  will be 

selected. 

Erase  Data

  –  pushing  buttons  R  and  L  (right  and  left  arrows)  simultaneously  will  delete  all  records  of 

measured parameters  (minimum and maximum temperature values of sensors A and  B). 

Beep Temp. A

 – adjustment of a Morsealphabet character which will announce violation of the set alert 

temperature of sensor A by an acoustic signal of the DUPLEX Tx transmitter module. 

Beep Temp. B

 – adjustment of a Morsealphabet character which will announce violation of the set alert 

temperature of sensor B by an acoustic signal of the DUPLEX Tx transmitter module. 
 

MT125  MENU: 

ALARMS

  –  by  pushing  button  D  (downward  arrow)  you  will  enter  the  adjustment 

modes  of  particular  alerts.  If  violation  of  a  set  parameter  occurs  the  indication  of  the  JETIBOX  LC 
display will show in the second line of the basic menu the original indication as well as the particular alert 
indication  alternately  and  the  siren  of  the  transmitter  module  will  emit  alert  signals.  The  first  tone  is  a 
reference signal and the second tone is the corresponding Morse signal of the particular alert. There will 
be no particular signal emitted if the alert is in OFF position.  

Temp.  High  A

  –  signal  adjustment  for  high  temperatures,  if  the  measured  temperature  exceeds  the  set 

value alert of sensor A will be activated. 

Temp. Low A

 – signal adjustment for low temperatures, if the measured temperature is below the set value 

alert of sensor A will be activated. 

Temp.  High  B

  –  signal  adjustment  for  high  temperatures,  if  the  measured  temperature  exceeds  the  set 

value alert of sensor B will be activated. 