MEZON 130
6-51V SBEC 6/15A
Measurement menu
Actual values >
Measurement menu
< Min/Max log. >
Max. Current
–
the maximum current drawn from the battery with motor run time
listed. (Calculated from the controller start point)
Max. Temperature
-
the maximum temperature of the controller with motor run time
listed. (Calculated from the controller start point)
Max. BEC current*
-
the maximum current drawn from the BEC with motor run tim
e
listed. (Calculated from the controller start point)
*this item is not available in the MEZON OPTO controller menu.
Max. Speed
–
maximum RPM with motor run time listed.
(Calculated from the controller start point)
Min. voltage
–
Minimum battery voltage with motor run time listed.
(Calculated from the controller start point)
Capacity/Run time
–
the consumed battery capacity and motor run time
24
5.
3
Statistics
During operation, MEZON controllers carry out a statistical analysis and also log
the data into its internal memory. After switching-on the controller, the data
logs of the preceding controller operation (flight) are displayed. This data is no
longer available once the motor is started. After 10 seconds of a new motor run
the stored data logs are deleted and a new data log starts – containing, of
course, the data from the first 10 seconds of operation.