User Manual: Electronic switch Main Switch
-5-
4.
Telemetry
The Main Switch can measure the voltage, current, consumed capacity of the battery connected in the model
and also the Main Switch temperature. Alarms can be set to monitor maximum current, minimum voltage,
maximum consumed capacity, and maximum temperature.
Use the JETIBOX or the DC/DS transmitters from JETI model (in the JETIBOX emulator) for parameter
adjustment and data readout. After the JETIBOX is connected to the Main Switch, the sensor identification is
shown and in the second line also the preadjusted actual measured data. By a long push of button R (right) a
fast deletion of all measured data can be triggered (min. and max. voltage, max. current, average current,
runtime, capacity). Fast deletion is indicated in the first line of the display by an asterisk „*“.
MENU: ACT. VALUES –
Volt. / Current –
displays actual measured voltage and current passing through the switch. By simultaneously
pushing arrows R and L (right and left) the zero value of the sensor current is calibrated. The actual measured
current value is added to the zero current display, i.e. the so called zero shift.
Capacity
– shows the actual consumed capacity.
Run Time
– shows the total time of current passage through the switch. Included is also the time when the
current has exceeded the adjusted current value
Start Trigger
in the
SETTING
menu.
MENU
:
MIN / MAX
– Display of extreme voltages and currents that occurred during the measurement. The
extreme recordings are deleted automatically or can be deleted in the menu „
SETTING – Erase Data“.
Automatic deletion occurs when the switch has just been connected to the voltage supply and the current, as
set in the menu
Setting-Start Trigger,
is exceeded. If after connection of the switch the set current is not
exceeded, values of the previous switch operation will be displayed.
U MIN / MAX
– Shows the minimum and maximum value of the measured voltage.
I AVG / MAX
– shows the average value of the measured current and its maximum.
MENU:
SETTING
– basic setting of the switch
Start Trigger
– setup of a current value, at which after switch connection, the recording of values like
minimum, maximum and current transit time starts. If the adjusted value is 0A, values will be recorded
immediately after the connection of the switch to its power supply and reading the data of the previous
operation will not be possible.
Erase Data
– by pushing arrows R and L (right and left) simultaneously the records of measured parameters
will be deleted.
First Parameter
– adjustment of the display of the first parameter in the JETIBOX LCD, which is shown in
the second line of the basic switch menu (the first line shows the identification, for instance MS 200)
Second Parameter
– adjustment of the display of the second parameter in the JETIBOX LCD, which is shown
in the second line of the basic sensor menu (the first line shows the identification, for instance MS 200)
Auto. Erase
– This function of automatic data deletion after overstepping the trigger level can be activated or
deactivated.