PAGE 32 of 54
Table 2
Code Value
Explanation
1
R/C Off
AUX switched to
Off
position or throttle stick and throttle trim moved to the
minimum position.
2
OverTemp
Turbine running over temperature. Exceeded high temperature parameter
and time out.
3
IgnTimOut
Turbine did not ignite within programmed time interval.
4
AccTimOut
Turbine achieved ignition, but did not accelerate within programmed time
interval.
5
Acc.Slow
Turbine achieved ignition, but acceleration was less than the programmed
value, during startup.
6
Over-RPM
Turbine exceeded the maximum RPM, by 5% and a delay of 0.5 seconds.
7
Low-RPM
Turbine running under the minimum RPM, by 10% and a delay of 3 seconds.
Usually triggered by a flame out.
8
BattryLow
Battery pack is dead. Cell voltage is < 1.0V.
9
Auto-Off
Turbine shut down via the
AutoOff
sequence, using the AUX channel.
10
LowTemp
EGT dropped below the minimum value. A dislodged EGT sensor can trigger
this shut down.
11
HiTempOff
EGT exceeded the maximum range (~950 °C).
12
GlowPlug!
Defective kero/glow plug.
13
WatchDog
ECU processor was locked out usually from static discharge or voltage spike
in power supply.
14
FailSafe
Turbine was shut down from a failsafe timeout condition.
15
ManualOff
Turbine was shut off by using the GSU.
16
PowerFail
The power failed to the ECU when the turbine was running. This will occur if
the power was lost because of a defective battery, connection or if the switch
is turned off before the engine is shut-down.
Note: If this state is displayed the Info, Min/Max and Statistics menus
retain information from the previous run.
17
TempSensor
Fail
EGT sensor failed.
Note: This could happen only during startup.
18
Wrong Pmp
Wrong pump type, see pump configuration in the advanced section of the
manual.
19
No Pump
There is either no pump connected or the pump cable is defective.
20
Over Curr
The electrical current to the engine is too high.
Starter may be jammed
Kero/glow plug is short circuited