www.jetgroupbrands.com
3.
Insert the Extracting Tube ( L ) into the dipstick
hole until it reaches the bottom of the oil pan.
Connect the Fluid Inlet Tube ( K ) into the Fluid
Inlet Coupler ( J ) with the Fluid Inlet Tube
Adapter.
The Fluid Inlet Tube ( K ) will connect to the
Extracting Tube ( L ) with the Extracting Tube
Adapter.
4.
Lift the Handle ( H ) of the Hand Pump ( G )
to the top position and press it to the bottom
position repeatedly.
The Extraction Pump will start operating.
5.
When the fluid inside the extractor tank reaches
"Full" position, the Extraction Pump will shut
off automatically, the Handle ( H ) of the Hand
Pump ( G ) wiII lock. Push the Pressure Release
Button ( B ) on the side of the Cover Housing
( A ), and then press the Handle ( H )of the
Hand Pump ( G ) to the bottom position to
release Hand Pump from locked position.
5