5
4.0
Specifications
Model number .........................................................................................................................................
JCDC-1.5
Stock number .............................................................................................................................................. 717515
Motor and electricals:
Motor
type
........................................................................
.totally enclosed fan cooled, induction, capacitor start
Horsepower
............................................................................................................................. 1-1/2 HP (1.1kW)
Phase
.......................................................................................................................................................... single
Voltage
................................................................................................................................................. 115V only
Cycle
............................................................................................................................................................ 60Hz
Listed FLA (full load amps) ........................................................................................................................... 14 A
Starting
amps
................................................................................................................................................ 52 A
Running amps (no load) ............................................................................................................................... 13 A
Start
capacitor
.......................................................................................................................... 300MFD 125VAC
Run
capacitor
..................................................................................................................................... 30
μ
F 250V
On/off
switch
...........................................................................................................
toggle switch with safety key
Motor
speed
........................................................................................................................................ 3450 RPM
Power
cord
........................................................................................................................ 14AWG x 3C, 6ft.,SJT
Power
plug
.................................................................................................................
5-15P, 125V/15A installed
Recommended circuit and fuse/breaker size
1
.............................................................................................. 20A
Sound
emission
2
............................................................................................................... 75 dB at 9.84 ft. (3m)
Remote control system ............................................ radio frequency (FCC approved); range up to 50 ft. (15 m)
RC
transmitter
battery
...................................................................................................................................... 9V
Performance:
Inlet
diameter
................................................................................................................................ 6 in. (152 mm)
Inlet adaptors, number of ................................................................................................................................... 2
Inlet adaptors, diameter of ............................................................................................................. 4in. (100 mm)
Filter efficiency .................................................................. 99% of 2 micron particles; 86% of 1 micron particles
US method
EU method
Air Flow with filters installed .............................. 763 CFM (1293 m
3
/hr) ........................ 1259 CFM (2134 m
3
/hr)
Air Velocity .......................................................... 3877 FPM (18.5 m/s) .......................... 6396 FPM (32.50 m/s)
Static pressure loss (WC) ............................ 1.535 inH
2
O (39 mmH
2
O) ......................2.677 inH
2
O (68 mmH
2
O)
Maximum static pressure loss (WC) .......... 8.268 inH
2
O (210 mmH
2
O) ....................8.268 inH
2
O (210 mmH
2
O)
Impeller:
Impeller
diameter
........................................................................................................................ 13 in. (330 mm)
Impeller
type
.......................................................................................................................................... radial fin
Impeller
material
.......................................................................................................................................... steel
Canister filter:
Filter
type
........................................................................................................
cartridge and spunbond polyester
Canister filter diameter ........................................................................................................ 14-9/16 in. (370 mm)
Canister filter length .............................................................................................................. 15-3/4 in. (400 mm)
Filter surface area .................................................................................................................... 21.53 sq. ft. (2m
2
)
Filter
efficiency
............................................................................................................. 99% of 2 micron particles
Cleaning system ............................................................................................................ manual scraper rotation
Collection drum:
Capacity
.................................................................................................................................................... 20 gal.
Diameter
............................................................................................................................. 16-9/16 in. (420 mm)
Height
............................................................................................................................... 19-11/16 in. (500 mm)
Material
........................................................................................................................................................ steel
1
Subject to local/national electrical codes. Recommendation based upon dedicated circuit.
2
The specified values are emission levels and are not necessarily to be seen as safe operating levels. As workplace
conditions vary, this information is intended to allow the user to make a better estimation of the hazards and risks
involved only.