background image

JET  

 

Troubleshooting JAT-414,-417,-418 Die Grinders

 

Any disassembly of the tool should be done by qualified service personnel. For problems not addressed 
below, contact JET technical service at 800-274-6846. 

Problem 

Possible cause 

Remedy 

Tool will not start. 

Air valve closed or obstructed. 

Open valve; clear any obstructions. 

Dirt or gum deposits on 
components. 

Flush tool with gum solvent. 
If problem persists, disassemble, 
clean and lubricate internal parts. 

Rotor vanes or other components 
are worn. 

Replace worn components. 
(Replace vanes as an entire set.) 

Throttle lever malfunction. 

Clean throttle lever mechanism to 
ensure free movement. Replace 
mechanism if needed. 

Bearing(s) worn. 

Disassemble and inspect bearing. 
Grease or replace as needed. 

Starts immediately as soon 
as air is connected without 
lever being pressed. 

Throttle valve malfunction. 

Inspect and repair throttle valve. 

Excessive or abnormal 
vibration. 

Improper lubrication. 

Lubricate properly according to 
instructions in this manual. 

Bearings worn. 

Disassemble and inspect bearing. 
Grease or replace as needed. 

Loss of power; erratic 
action. 

Low air pressure. 

Verify compressor has proper CFM 
rating for tool. 
Check compressor regulator 
setting; set air pressure to 90 psi.   
Check for loose connections at air 
inlet, o-rings, etc.  

Moisture or obstruction in air 
hose. 

Air supply must be clean and dry. 
Clean out air hose(s) and remove 
any kinks or bends. 

Improper size of air transmission 
lines, hoses, fittings, or 
couplings. 

Use appropriate-sized air 
lines/hoses. 
Verify proper fittings/couplings. 

Dirt or gum deposits on 
components. 

Flush tool with gum solvent. 
Check and clean air filter on 
compressor.  
Clean external areas of tool. If 
problem persists, disassemble, 
clean and lubricate internal parts. 

Rotor vanes are worn. 

Replace vanes (entire set). 

Severe air leakage. 
(Note: Minimal escape of 
air is often normal for air 
tools.) 

Air valve obstructed or damaged. 

Clean or replace. 

Housing loose or damaged. 

Tighten or replace as needed. 

Excessive heat develops 
in tool. 

Improper lubrication. 

Lubricate properly according to 
instructions in this manual. 

Summary of Contents for JAT-414

Page 1: ...rinders 505414 JAT 414 505417 JAT 417 505418 JAT 418 Operation Manual M 505414 Edition 1 05 2019 JET 427 New Sanford Road LaVergne TN 37086 Ph 800 274 6848 www jettools com Copyright 2019 JET JAT 417...

Page 2: ...ecuring the tooling in the retainer and placing the tip against the work surface 11 Do not operate air tool without its guards in place Do not modify the tool 12 Do not operate this tool while tired o...

Page 3: ...of tool attachment must equal or exceed rated free speed of die grinder 36 Make sure attachment is securely inserted into collet and collet nut is tight 37 Make sure workpiece is secure and will not s...

Page 4: ...encompass all possible workplace environments The operator is expected to take appropriate precautions and exercise common sense As with any tool operation safety of operator and bystanders should be...

Page 5: ...power 1 91 dB A 94 dB A 93 dB A Sound pressure 1 80 dB A 83 dB A 82 dB A Grip Inline Inline Inline Overall Length 7 in 178 mm 9 60 in 243 8 mm 7 in 178 mm Housing material Composite Composite Composit...

Page 6: ...p tool with both hands and push safety lever forward to release throttle lever Gently press throttle lever 6 Release throttle lever to stop die grinder Maintenance Lubrication The die grinder should b...

Page 7: ...ench is too small or the air compressor CFM is not powerful enough for the job Continued use in either capacity will cause damage to the tool Tool Pressure JET Air Tools operate on 70 to 100 psi pound...

Page 8: ...8 JAT 414 417 418 Die Grinders Figure 2 Recommended arrangement of air piping and air line system...

Page 9: ...roperly according to instructions in this manual Bearings worn Disassemble and inspect bearing Grease or replace as needed Loss of power erratic action Low air pressure Verify compressor has proper CF...

Page 10: ...orized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Info...

Page 11: ...JET 11...

Page 12: ...12 JAT 414 417 418 Die Grinders 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com...