background image

4

3.0

Table of contents

Section

Page

1.0 IMPORTANT SAFETY INSTRUCTIONS ....................................................................................................... 2
2.0 About this manual .......................................................................................................................................... 3
3.0 Table of contents............................................................................................................................................ 4
4.0 Specifications for IAFS-series Air Filtration System....................................................................................... 5

4.1 Mounting hole spacing ............................................................................................................................... 7

5.0 Electrical connections .................................................................................................................................... 8

5.1 GROUNDING INSTRUCTIONS ................................................................................................................. 8
5.2 Extension cords.......................................................................................................................................... 8

6.0 Unpacking ...................................................................................................................................................... 9

6.1 Carton contents .......................................................................................................................................... 9

7.0 Installation ...................................................................................................................................................... 9
8.0 Controls and features ..................................................................................................................................... 9
9.0 Operation ....................................................................................................................................................... 9
10.0 User-maintenance...................................................................................................................................... 11

10.1 Transmitter replacement ........................................................................................................................ 11
10.2 Additional servicing ................................................................................................................................ 11

11.0 Optional accessories.................................................................................................................................. 11
12.0 Replacement parts ..................................................................................................................................... 11

12.1.1 IAFS-1700 Industrial Air Filtration System – Exploded View............................................................... 12
12.1.2 IAFS-1700 Industrial Air Filtration System – Parts List ....................................................................... 13
12.2.1 IAFS-2400 Industrial Air Filtration System – Exploded View............................................................... 14
12.2.2 IAFS-2400 Industrial Air Filtration System – Parts List ....................................................................... 15
12.3.1 IAFS-3000 Industrial Air Filtration System – Exploded View............................................................... 16
12.3.2 IAFS-3000 Industrial Air Filtration System – Parts List ....................................................................... 17

13.0 Electrical Connections................................................................................................................................ 18

13.1 Wiring diagram for IAFS-1700................................................................................................................ 18
13.2 Wiring diagram for IAFS-2400 and IAFS-3000....................................................................................... 19

14.0 Warranty and service ................................................................................................................................. 20

Summary of Contents for IAFS-1700

Page 1: ...ad LaVergne Tennessee 37086 Part No M 415100 Ph 800 274 6848 Edition 1 11 2020 www jettools com Copyright 2020 JET Operating Instructions and Parts Manual Industrial Air Filtration System Models IAFS 1700 IAFS 2400 IAFS 3000 ...

Page 2: ...eiling mounted bottom of filtration unit must be at least 7 feet from the floor 13 If ceiling mounted mounts must be anchored to building structure which will support the weight of the air filtration unit Never mount to surfaces such as dry wall or false ceiling grids 14 To reduce risk of electric shock do not expose filtration unit to water or rain 15 Never duct a machine directly into the air fi...

Page 3: ...ecautions general operating procedures maintenance instructions and parts breakdown Your machine has been designed and constructed to provide consistent long term operation if used in accordance with the instructions as set forth in this document If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site www jettools com Retain this manual ...

Page 4: ...lacement 11 10 2 Additional servicing 11 11 0 Optional accessories 11 12 0 Replacement parts 11 12 1 1 IAFS 1700 Industrial Air Filtration System Exploded View 12 12 1 2 IAFS 1700 Industrial Air Filtration System Parts List 13 12 2 1 IAFS 2400 Industrial Air Filtration System Exploded View 14 12 2 2 IAFS 2400 Industrial Air Filtration System Parts List 15 12 3 1 IAFS 3000 Industrial Air Filtration...

Page 5: ...372 1129 798 1946 1640 1269 2780 2364 1711 Total pressure Pa 3 53 2 46 1 18 7 16 5 10 3 04 7 65 5 60 2 94 Total pressure efficiency t 0 32 0 24 0 12 0 85 0 65 0 41 0 64 0 52 0 28 Filters installed Air flow CFM 1107 1008 805 1415 1325 1182 2099 1953 1666 Total pressure Pa 2 35 1 96 1 18 3 73 3 34 2 65 4 32 3 83 2 75 Total pressure efficiency t 0 19 0 20 0 13 0 41 0 43 0 37 0 34 0 36 0 28 Blower spe...

Page 6: ...r a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarante...

Page 7: ...7 4 1 Mounting hole spacing All measurements in millimeters Figure 4 1 Figure 4 2 ...

Page 8: ...s properly grounded Failure to comply may cause serious or fatal injury Use only 3 wire extension cords that have 3 prong grounding plugs and 3 pole receptacles that accept the tool s plug Repair or replace damaged or worn cord immediately 2 Grounded cord connected tools intended for use on a supply circuit having a nominal rating less than 150 volts This tool is intended for use on a circuit that...

Page 9: ...ight of the unit Do not mount to dry wall or false ceiling grids Failure to comply may cause serious injury and property damage If setting unit on a table or bench remove the adhesive from the 4 foot pads and press the pads to the bottom of the unit near the corners Remove back cover of remote controller and install 9 volt battery Reinstall cover The holder for the remote controller can be mounted...

Page 10: ...10 Figure 9 1 Figure 9 2 Figure 9 3 ...

Page 11: ...rn ON the Air Filtration Unit at the switch 2 On the remote control transmitter press and hold the On Off button for 3 seconds until a beep is heard 3 The remote controller will now operate the Air Filtration Unit 10 2 Additional servicing Any additional servicing should be performed by authorized service personnel 11 0 Optional accessories Charcoal carbon filters are especially effective at trapp...

Page 12: ...12 12 1 1 IAFS 1700 Industrial Air Filtration System Exploded View ...

Page 13: ...07 Inner Filter 1 20 415105 Charcoal Filter Optional 1 21 IAFS1700 021 Cabinet Assembly 1 22 IAFS1700 022 Eye Bolt M6 4 23 IAFS1700 023 Fixing Plate 2 24 IAFS1700 024 Gasket 2 25 330025 Air Diffuser 1 26 IAFS RC Remote Control Transmitter includes holder 1 9 volt Battery local purchase 1 27 IAFS1700 027 Foam foot pad 4 28 IAFS1700 028 Blower Assembly includes 101 thru 111 1 101 330005 Motor Gasket...

Page 14: ...14 12 2 1 IAFS 2400 Industrial Air Filtration System Exploded View ...

Page 15: ... Cabinet Assembly 1 22 330025 Air Diffuser 1 23 JWBS14DP 6 8 Carriage Bolt M8 x 16 4 24 TS 1540061 Hex Nut M8 10 25 IAFS RC Remote Control Transmitter includes holder 1 26 IAFS1700 027 Foam foot pad 4 27 IAFS2400 028 Blower Assembly includes 101 thru 114 1 101 TS 1534032 Pan HD Phillips Mach Screw M6 x 10 4 102 TS 1534042 Pan HD Phillips Mach Screw M6 x 12 4 103 IAFS2400 103 Blower Housing 1 104 T...

Page 16: ...16 12 3 1 IAFS 3000 Industrial Air Filtration System Exploded View ...

Page 17: ...r Diffuser 1 22 TS 1540061 Hex Nut M8 10 23 JWBS14DP 6 8 Carriage Bolt M8 x 16 4 24 TS 1490021 Hex Cap Screw M8 x 16 6 25 IAFS RC Remote Control Transmitter includes holder 1 26 IAFS1700 027 Foam foot pad 4 27 IAFS3000 028 Blower Assembly includes 101 thru 114 1 101 TS 1534032 Pan HD Phillips Mach Screw M6 x 10 4 102 TS 1534042 Pan HD Phillips Mach Screw M6 x 12 4 103 IAFS3000 103 Blower Housing 1...

Page 18: ...18 13 0 Electrical Connections 13 1 Wiring diagram for IAFS 1700 ...

Page 19: ...19 13 2 Wiring diagram for IAFS 2400 and IAFS 3000 ...

Page 20: ...itional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How State Law App...

Reviews: