14
Changing Operating Frequency
If several devices are controlled by the same type
remote control unit, each remote control unit can be
set to operate at its’ own unique operating frequency
as follows:
Referring to Figure 15:
1. Unplug the DC-RC
Remote Power Control
unit.
2. Remove the back covers of the
main unit
(A) and
remote control switch
(B).
3. Locate
the
DIP switch
(C) in each unit.
4. Change the position of the DIP switches in the
main unit
(A) to any combination desired as long
as they are not the same as other units that may
be present and located within the radio frequency
range.
5. Set the
DIP
switches
(C) in the
remote control
switch
(B) to match the switch settings in the
main unit
(A).
6. Replace the back covers to the main unit and
remote control switch.
7. Operate a device as described in
Turning the
DC-RC On & Off
and verify that other devices
using the same type remote control do not turn
on.
Figure 15
Installing the DC-RC Remote Power
Control
(Optional Accessory)
The
DC-RC Remote Power Control
unit can be
placed anywhere for convenience and portability if
used to control other machines or it can be mounted
as a permanent part of a machine, such as the DC-
1100VX Dust Collector.
To mount the
DC-RC Remote Power Control
(refer to
Figure 16):
Note:
Mounting hardware is not included and must
be supplied by the machine’s owner or user.
1. Place
RC Power Control Unit
(A) on the open
clearing of the
base
(B) of the dust collector near
the
motor
(C).
2. Using a marker, mark the base through the
mounting holes of the power control units
mounting tabs.
3. Drill two holes (D) through the base where
marked.
4. Insert screws through the tabs and base. Place
washers and hex nuts on the threaded ends of
the screw underneath the base and tighten.