7.2  Extension Cords 

The use of extension cords is discouraged. Try to 
position machines within reach of the power source. 
If an extension cord must be used, make sure it is 
heavy enough to carry the current your product will 
draw. An undersized cord will cause a drop in line 
voltage resulting in loss of power and overheating. 
Table  2  shows  correct  size  to  use  depending  on 
cord  length  and  nameplate  ampere  rating.  If  in 
doubt, use the next heavier gauge. The smaller the 
gauge number, the heavier the cord. 

Ampere 
Rating 

Volts  Total length of cord in feet 

More 
Than 

Not 
More 
Than 

120 

25 

50 

100 

150 

 

AWG 

0

0

 

18 

16 

16 

14 

0

10 

 

18 

16 

14 

12 

10 

12 

 

16 

16 

14 

12 

12 

16 

 

14 

12 

Not 
Recommended 

Extension Cord Recommendations 

Table 2 

 

8.0  Controls Functions 

8.1  Control Panel Buttons 

 

Figure 8-1 

 

POWER ON/OFF SWITCH – A 

The Power ON/OFF Switch (Fig. 8-1, A) is a rocker 
switch on the control panel used to supply power to 
the AFS electronic controls and thus the full AFS. 

In the OFF position, AC power is disconnected from 
the electronics. The AFS unit will not turn On. 

In  the  ON  position,  AC  power  is  connected  to  the 
electronics.  The  electronics  are  powered  On  in  a 
STANDBY state awaiting user input via the ON/OFF 
Button (B). 

ON/OFF BUTTON – B 

When the Power ON/OFF Switch (Fig. 8-1, A) is first 
turned ON, power is supplied to the electronics and 
the AFS unit is in the STANDBY state. All DISPLAYs 
are off. 

Each  press  of  the  ON/OFF  Button  (Fig.  8-1,  B) 
cycles the AFS unit between STANDBY and ON. 

Pressing the ON/OFF Button once: 

 

AFS Unit goes to ON state. 

 

The TIMER DISPLAY is blank. 

 

The fan starts to run at speed 1. 

 

The SPEED DISPLAY shows 1 bar for speed 1. 

 

The  FILTER  DISPLAY  will  illuminate  the  filter 
status. 

Pressing  the  ON/OFF  Button  again  does  the 
following: 

 

AFS unit goes to STANDBY state. 

 

All DISPLAYS are off, and the fan stops. 

TIMER  

The TIMER may be set in 1-hour increments from 1 
to 16 hours. When the timer expires, the fan will stop 
and the AFS will enter STANDBY state. 

When  the  timer  is  not  being  used,  the  TIMER 
Display  will  be  blank  and  the  AFS  will  run 
continuously until the user changes the settings or 
stops the AFS. 

To activate the TIMER, press the TIMER + Button. 

 

The  TIMER  DISPLAY  changes  from  blank  to 
display flashing “1”. This is 1 hour. 

 

Pressing  the  TIMER  +  Button  again  will 
increase the number by 1 each time the TIMER 
+  Button  is  pressed.  Up  to  a  maximum  of  16 
hours. 

 

Pressing the TIMER – Button will decrease the 
number by 1 each time the TIMER - Button is 
pressed.  Down  to  a  blank  display  turning  the 
TIMER Off and running the AFS continuously. 

 

If the display is already set and showing an hour 
time  value,  then  pressing  the  TIMER  +  or  – 

Summary of Contents for AFS-850

Page 1: ... 427 New Sanford Road LaVergne Tennessee 37086 Part No M JT1 229 Ph 800 274 6848 Edition 1 09 2023 www jettools com Copyright 2023 JET Operating Instructions and Parts Manual AFS 850 Air Filtration System ...

Page 2: ...a two prong receptacle the adapter lug must be attached to a known ground Never remove the third prong 15 WARNING Drilling sawing sanding or machining wood products generates wood dust and other substances known to the State of California to cause cancer Avoid inhaling dust generated from wood products or use a dust mask or other safeguards to avoid inhaling dust generated from wood products Wood ...

Page 3: ...ces used in this manual This means that if precautions are not heeded it may result in minor injury and or possible machine damage This means that if precautions are not heeded it may result in serious or possibly even fatal injury SAVE THESE INSTRUCTIONS ...

Page 4: ...Cleaning the Filters 13 10 2 1 Washable Pre Filter 13 10 2 2 Cleaning Canister Filter 13 10 4 Cleaning Sensors 14 10 5 Sensor Replacement 14 10 6 Control Board Replacement 14 11 0 Troubleshooting 15 12 0 Replacement Parts 16 12 1 1 AFS 850 Unit Exploded View 16 12 1 2 AFS 850 Unit Parts List 17 12 2 1 Display Module Assembly Exploded View 18 12 2 2 Display Module Assembly Parts List 18 12 3 1 Lowe...

Page 5: ...nual is not intended to be an exhaustive guide to air filtration systems Additional knowledge can be obtained from experienced users or trade articles Whatever accepted methods are used always make personal safety a priority If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site www jettools com Retain this manual for future reference I...

Page 6: ...Improved durability o Quieter operation o More energy efficient Auto Mode o In Auto Mode the unit monitors ambient air quality using an integrated PM2 5 sensor and adjusts fan speed to compensate o More air flow when it s needed to quickly improve air quality o Save energy and filter life when dust levels are low Power Cord Length 15ft Pre Filter non woven washable Canister Filter 1 Micron 98 Opti...

Page 7: ...merican Type NEMA 10A 125V Overload protector 5A Performance Fan Speed Air flow without filter CFM 1 Sound rating 1m 1 1 450 10 51dB 2 530 10 54dB 3 610 10 56dB 4 690 10 58dB 5 770 10 60dB 6 850 10 64dB Control Panel On off switch Rocker switch Speed control Six selectable speeds Timer Setting Hour 1 16 LED display Display LED module Auto Mode Sensor detects air quality and adjusts fan speed accor...

Page 8: ...Gross Weight 40 39 lb 18 36 kg 1 Variable of 10 for general information only not to be viewed as fixed parameters for inspection purposes L length W width H height n a not applicable The specifications in this manual were current at time of publication but because of our policy of continuous improvement JET reserves the right to change specifications at any time and without prior notice without in...

Page 9: ...evant codes Failure to comply may cause serious injury The AFS 850 Air Filtration System is prewired for single phase 120V power It is provided with a plug designed for use on a circuit with a grounded outlet that looks like the one pictured in Figure 7 1 It is recommended that the AFS 850 be connected to a 15 amp circuit with a circuit breaker or fuse If fuses are used they should be time delay f...

Page 10: ...tton B ON OFF BUTTON B When the Power ON OFF Switch Fig 8 1 A is first turned ON power is supplied to the electronics and the AFS unit is in the STANDBY state All DISPLAYs are off Each press of the ON OFF Button Fig 8 1 B cycles the AFS unit between STANDBY and ON Pressing the ON OFF Button once AFS Unit goes to ON state The TIMER DISPLAY is blank The fan starts to run at speed 1 The SPEED DISPLAY...

Page 11: ...the fan speed AUTOMATIC MODE NOTE For best performance in AUTO Mode allow adequate air flow to the sensor on the front of the unit see Fig 8 3 Figure 8 3 When the AUTO Button is pressed the AUTO Button is illuminated and the AFS is operating in AUTO Mode In AUTO Mode the integrated sensor detects the air quality and adjusts the fan speed accordingly Thereby reducing energy consumption when air qua...

Page 12: ...e such as a weekend or vacation turn the Power On Off Switch to Off 10 0 User Maintenance Always disconnect power to the machine before performing maintenance Failure to do this may result in serious personal injury 10 1 Changing the Filters To reduce the risk of injury disconnect the air filtration system from the power source unplug before servicing or changing filters Failure to comply may caus...

Page 13: ...re Filter and the Canister Filter at the same time Whether using the Filter Status Indicator or a visual inspection both filters should be cleaned to restore as much filtration ability as possible Remove the filters from the AFS unit as described in 10 1 Changing the Filters 10 2 1 Washable Pre Filter The Pre Filter p n AFS850 008 is washable and must be dry before returning to service Using a hos...

Page 14: ...the sensor should need replacing follow these instructions to calibrate the new sensor 1 With the Power ON OFF Switch Fig 10 4 A in the OFF position press and hold the Timer DN and Timer UP buttons simultaneously and switch the Power ON OFF Switch to the ON position to enter the environment value setting mode 2 The screen flashes and displays the calibration is completed when the detected value is...

Page 15: ...el replace if needed Unit not working efficiently not cleaning air Filter not installed properly Reinstall filter Blocked air flow Inspect filter replace if clogged remove blockage Controls on unit not working Control button or PCBA malfunction Contact JET customer service Timer screen displays numbers letters other than a countdown timer If screen displays A8 filter is not installed Install filte...

Page 16: ...To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately 12 1 1 AFS 850 Unit Exploded View ...

Page 17: ...AFS850 019 Plastic base 1 20 AFS850 PBCA Plastic base cover assembly 1 21 JET 56B JET stripe 5 12 x 6 10 1 22 AFS850 022 Warning label 1 23 AFS850 MD Model decal AFS 850 1 24 AFS1000C 025 Flat head screw tapping screw M4 x 10 4 25 AFS1000C DM8 Screw pan head Phillips tapping screw M3 x 10 4 26 AFS1000C 025 Flat head screw tapping screw M4 x 10 4 27 AFS1000C 032 Screw flanged hex head Phillips M6 x...

Page 18: ...6 4 AFS850 DM4 Display cover 1 6 5 AFS850 DM5 Display PCB 1 6 6 AFS1000C DM6 Screw pan head Phillips tapping screw M3 x 6 6 12 3 1 Lower Panel Cover Assembly Exploded View 12 3 2 Lower Panel Cover Assembly Parts List Index No Part No Description Size Qty 7 AFS850 PLCA Panel lower cover assembly 1 7 1 AFS850 PLC1 Panel lower cover 1 7 2 AFS850 PLC2 Dust sensor fan 1 7 3 AFS1000C 014 Dust sensor 1 7...

Page 19: ... Cover Assembly Parts List Index No Part No Description Size Qty 20 AFS850 PBCA Plastic base cover assembly 1 20 1 AFS850 PBC1 Plastic base cover 1 20 2 AFS850 PBC2 Counterweights 1 20 3 AFS850 PBC3 Hex nylon nut 1 20 4 AFS850 PBC4 Screw flanged hex head Phillips M6 x 16 1 ...

Page 20: ...20 13 0 Electrical Connections 115V ...

Page 21: ...itional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How State Law App...

Page 22: ...22 NOTES ...

Page 23: ...23 NOTES ...

Page 24: ...24 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...

Reviews: