background image

 11

8.0  Controls Functions 

8.1  Control Panel Buttons 

 

 

Figure 8-1 

8.2  RF Remote Control 

 

 

Figure 8-2 

 

POWER ON/OFF SWITCH 

 A 

The Power ON/OFF switch (Fig. 8-1, A) is a rocker 
switch on the control panel used to supply power to 
the AFS electronic controls and thus the full AFS. 

In the OFF position, AC power is disconnected from 
the electronics. The AFS unit will Not turn On. 

In  the  ON  position,  AC  power  is  connected  to  the 
electronics.  The  electronics  are  powered  On  in  a 
STANDBY state awaiting user input via the ON/OFF 
button on either the control panel or the remote. 

 

ON/OFF BUTTON (control panel or 

remote) 

 B 

The  On/Off  Button  (Fig.  8-1  and  8-2,  B)  on  the 
controls  and  the  remote  perform  the  exact  same 
function under the exact same conditions. 

When the Power switch (Fig. 8-1, A) is first turned 
ON,  power  is  supplied  to  the  electronics  and  the 
AFS  unit  is  in  the  STANDBY  state.  All  DISPLAYs 
are off. 

Each press of the ON/OFF button (Fig. 8-1 and 8-2, 
B) cycles the AFS unit between STANDBY and ON. 

Pressing the ON/OFF button once: 

 

AFS Unit goes to ON state. 

 

The TIMER DISPLAY is blank. 

 

The fan starts to run at speed 1. 

 

The SPEED DISPLAY shows 1 bar for speed 1. 

 

The  FILTER  DISPLAY  will  illuminate  the  filter 
status. 

Pressing  the  ON/OFF  button  again  does  the 
following: 

 

AFS unit goes to STANDBY state. 

 

All DISPLAYS are off, and the fan stops. 

TIMER (control panel or remote) 

The  TIMER  buttons  (Fig.  8-1  and  8-2)  on  the 
controls  and  the  remote  perform  the  exact  same 
function under the exact same conditions. 

The TIMER may be set in 1-hour increments from 1 
to 16 hours. When the timer expires, the fan will stop 
and the AFS will enter STANDBY state. 

When the timer is not being used, the TIMER display 
will be blank and the AFS will run continuously until 
the user changes the settings or stops the AFS. 

To activate the TIMER, pressing the TIMER + button. 

 

The  TIMER  DISPLAY  changes  from  blank  to 

display flashing “1”. This is 1 hour.

 

 

Pressing the TIMER + button again will increase 
the number by 1 each time the TIMER + button 
is pressed. Up to a maximum of 16 hours. 

 

Pressing the TIMER 

 button will decrease the 

number  by  1  each  time  the  TIMER  -  button  is 
pressed.  Down  to  a  blank  display  turning  the 
TIMER Off and running the AFS continuously. 

 

If the display is already set and showing an hour 
time  value,  then  pressing  the  TIMER  +  or 

 

button will add or subtract time from the already 
set value. 

 

When  the  TIMER  +  or 

  button  have  been 

pressed, the number on the TIMER display will 
flash  for  1  second  and  then  show  steady  ON. 
Steady ON indicates the TIMER is set and the 
countdown has begun. 

 

Pressing  and  holding  either the  TIMER  +  or 

 

button  (2  seconds)  will  advance  the  count 
quickly  (changing  every  0.2  seconds)  until  the 
button is released. 

 B 

Summary of Contents for AFS-1000C

Page 1: ... 427 New Sanford Road LaVergne Tennessee 37086 Part No M 713000 Ph 800 274 6848 Edition 3 12 2021 www jettools com Copyright 2021 JET Operating Instructions and Parts Manual AFS 1000C Air Filtration System ...

Page 2: ...sed to accommodate a two prong receptacle the adapter lug must be attached to a known ground Never remove the third prong 15 WARNING Drilling sawing sanding or machining wood products generates wood dust and other substances known to the State of California to cause cancer Avoid inhaling dust generated from wood products or use a dust mask or other safeguards to avoid inhaling dust generated from ...

Page 3: ...device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device This equipment complies with IC RSS 102 radiation exposure limits set forth for an uncontrolled environment L émetteur récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d Innovation Sciences et Développement économique ...

Page 4: ...0 Operation 12 10 0 User maintenance 13 10 1 Changing the Filters 13 10 2 Cleaning the Filters 13 10 2 1 Washable Filters 13 10 2 2 Dry Filters 14 10 3 RF Remote Control Replacement 14 10 4 Cleaning Sensors 14 10 5 Sensor Replacement 14 10 6 Control Board Replacement 14 11 0 Troubleshooting 15 12 0 Replacement Parts 16 12 1 1 AFS Unit Exploded View 16 12 1 2 AFS Unit Parts List 17 12 2 1 Display M...

Page 5: ...tended to be an exhaustive guide to air filtration systems Additional knowledge can be obtained from experienced users or trade articles Whatever accepted methods are used always make personal safety a priority If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site www jettools com Retain this manual for future reference If the machine ...

Page 6: ...CE o Fan Speed 6 levels o Timer setting 1 to 16 hours in 1 hour increments automatically shuts off when timer runs out High efficiency Brushless DC motor o Improved durability o Quieter operation o More energy efficient Auto Mode o In Auto Mode the unit monitors ambient air quality using an integrated PM2 5 sensor and adjusts fan speed to compensate o More air flow when it s needed to quickly impr...

Page 7: ...125V Overload protector 5A Performance Fan Speed Air flow without filter CFM 1 Sound rating 1m 1 1 450 10 51dB 2 560 10 56dB 3 670 10 60dB 4 780 10 63dB 5 890 10 66dB 6 1000 10 67dB Control Panel On off switch Rocker switch Speed control Six selectable speeds Timer Setting Hour 1 16 LED display Display LED module Digital Remote Control Transmitter Radio Frequency Battery CR2032 3 Volt Button Cell ...

Page 8: ...eight lbs 41 8lbs 19 kg 1 Variable of 10 for general information only not to be viewed as fixed parameters for inspection purposes L length W width H height n a not applicable The specifications in this manual were current at time of publication but because of our policy of continuous improvement JET reserves the right to change specifications at any time and without prior notice without incurring...

Page 9: ... be capable of supporting the weight of the air filtration unit and absorbing any vibrations arising from the unit Appropriate fasteners must be used to secure to the ceiling Failure to comply may cause serious injury Never mount to surfaces such as dry wall false ceiling grids etc When overhead mounting such as a ceiling make sure chain and ceiling hooks are properly rated for hanging this unit R...

Page 10: ...reen with or without yellow stripes is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding conductor to a live terminal Check with a qualified electrician or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the tool is properly grounded Failure to comply...

Page 11: ...ing AFS unit goes to STANDBY state All DISPLAYS are off and the fan stops TIMER control panel or remote The TIMER buttons Fig 8 1 and 8 2 on the controls and the remote perform the exact same function under the exact same conditions The TIMER may be set in 1 hour increments from 1 to 16 hours When the timer expires the fan will stop and the AFS will enter STANDBY state When the timer is not being ...

Page 12: ...e AUTO mode and return to manual mode NOTE In AUTO mode the unit may require several minutes to return to fan speed 1 once dust is detected The unit intentionally ramps down slowly to ensure good shop air quality FILTER STATUS INDICATOR control panel The FILTER status indicators are located on the control panel and are there to indicate the condition of the filters GOOD indicates that the filters ...

Page 13: ... To reduce the risk of injury disconnect the air filtration system from the power source unplug before servicing or changing filters Failure to comply may cause serious injury This AFS is designed to remove airborne non metallic dust particles from the air Cleaning is about removing those particles from the filter in the opposite direction from which it came It is recommended to clean both filters...

Page 14: ...he ON OFF button 3 Press and hold the SPEED minus and SPEED plus buttons on the control panel at the same time and hold for two seconds The screen flashes 0 5 seconds and displays to enter the programming mode 4 Press and hold the ON OFF button of the REMOTE control until the panel is turned ON ON is displayed and the programming is complete 5 In the programming mode press any other button on the ...

Page 15: ...dentify sources of interference and eliminate them or relocate unit Remote control or machine control panel malfunction Contact JET customer service Unit not working efficiently not cleaning air Filter not installed properly Reinstall filter Blocked air flow Inspect filter replace if clogged remove blockage Controls on unit not working Control button or PCBA malfunction Contact JET customer servic...

Page 16: ...s To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately 12 1 1 AFS Unit Exploded View ...

Page 17: ...ssembly SEE 12 3 1 for detail 1 21 AFS1000C 021 Eye bolt M6X20 4 22 AFS1000C 022 Standoff M6X25 4 23 TS 1550041 Flat washer M6 13 24 TS 1534032 Screw Pan Head Phillips M6X10 5 25 TS 2286202 Screw Pan Head Phillips M6X20 2 26 AFS1000C 023 Hex head bolt M6X300 6 27 TS 1551041 Spring washer M6 7 28 AFS1000C 024 Screw Pan Head Phillips Tapping screw M5X12 8 29 AFS1000C 025 Flat head screw Tapping scre...

Page 18: ...isplay Module Assembly 1 8 1 AFS1000C DM1 AC power switch 1 8 2 AFS1000C DM2 Display label 1 8 3 AFS1000C DM3 Auto button 1 8 4 AFS1000C DM4 Display cover 1 8 5 AFS1000C DM5 Display PCB 1 8 6 AFS1000C DM6 Screw Pan Head Phillips Tapping screw M3X6 6 8 7 AFS1000C DM7 Control module 1 8 8 AFS1000C DM8 Screw Pan Head Phillips Tapping screw M4X10 4 ...

Page 19: ...escription Size Qty 20 AFS1000C RCA Remote Control Assembly 1 20 1 AFS1000C RC1 Remote label 1 20 2 AFS1000C RC2 Remote front case 1 20 3 AFS1000C RC3 Remote PCB 1 20 4 AFS1000C RC4 Button cell CR2032 1 20 5 AFS1000C RC5 Remote rear case 1 20 6 AFS1000C RC6 Battery cover 1 20 7 AFS1000C RC7 Remote FCC label 1 ...

Page 20: ...20 13 0 Electrical Connections 115V Power Switch Display PCB CN1 CN2 CN2 Control Module Motor Thermal Fuse Power Cord Dust Sensor ...

Page 21: ...itional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How State Law App...

Page 22: ...22 NOTES ...

Page 23: ...23 NOTES ...

Page 24: ...24 427 New Sanford Road LaVergne Tennessee 37086 Phone 800 274 6848 www jettools com ...

Reviews: