background image

7

4.

The lock nut needs to be threaded almost all
the way up the eyebolt. Screw the eye bolt
into the hole and tighten lock nut against the
cabinet top.

You will need to hold the

eyebolt so it does not spin while tightening
the lock nut.

5.

Repeat steps for remaining three eyebolts.

Note: Make sure chain and ceiling hooks are
properly rated for hanging this unit. Hang unit
with a seven-foot clearance from the floor.

CAUTION!

Mounts must be anchored to building

structure, which will support a minimum of

at least 100 pounds. Never mount to

surfaces such as dry wall or false ceiling

grids, etc.

1.

Four brackets can also be used for mounting
to the ceiling, or wall.

2.

Place one end of bracket underneath the lip
of the cabinet.

3.

Attach the bracket (A, Fig. 2) with two hex
cap screws (B, Fig. 2) and two lock washers
(C, Fig. 2).

4.

Repeat steps for remaining three brackets.

5.

Peel off the paper backing, on the foam
pads, and stick to the bottom side of the
machine’s four corners.

Controls and Features

Remote Control:

Time button (A, Fig. 3) controls the three
different settings.

2H will light up on the back of the unit with one
press of the time button.

The air filtration

system will operate for 2 hours then shut off.

4H will light up on the back of the unit by
pressing the time button twice. The air filtration
system will operate for 4 hours then shut off.

8H will light up on the back of the unit by
pressing the time button three times.

The air

filtration system will operate for 8 hours then
shut off.

Summary of Contents for AFS-1000B

Page 1: ...OWNER S MANUAL AFS 1000B Air Filtration JET EQUIPMENT TOOLS INC P O BOX 1349 253 351 6000 A WMH Company Auburn WA 98071 1349 Fax 800 274 6840 www jettools com e mail jet jettools com M 708620 5 01...

Page 2: ...accidents normal wear and tear repair or alterations outside our facilities or to a lack of maintenance THE JET GROUP LIMITS ALL IMPLIED WARRANTIES TO THE PERIOD SPECIFIED ABOVE FROM THE DATE THE PRO...

Page 3: ...ep tools sharp and clean for best and safest performance Follow instructions for lubricating and changing accessories 16 DISCONNECT TOOLS before servicing and when filters 17 USE RECOMMENDED ACCESSORI...

Page 4: ...cian or service personnel if the grounding instructions are not completely understood or if in doubt as to whether the tool is properly grounded Use only three wire extension cords that have three pro...

Page 5: ...changing filters 3 If ceiling mounted bottom of air cleaner must be at least 7 feet above the floor 4 If ceiling mounted mounts must be anchored to building structure which will support a minimum of a...

Page 6: ...st if it is located away from corners and heating cooling vents If using on sawhorses the air filtration unit should be clamped in place This unit is specifically designed to circulate and filter non...

Page 7: ...ceiling or wall 2 Place one end of bracket underneath the lip of the cabinet 3 Attach the bracket A Fig 2 with two hex cap screws B Fig 2 and two lock washers C Fig 2 4 Repeat steps for remaining thr...

Page 8: ...lters Failure to comply may cause serious injury There are two filters that need to be changed The outer filter can easily be removed by disengaging the two clips A Fig 5 Now you can simply pull the f...

Page 9: ...9 Parts Breakdown...

Page 10: ...g 1 25 OO1057 Motor 1 CA001000B Capacitor not shown 1 26 NF050800 Nut M5 4 28 708711 Remote Control 1 29 330004 Flange 1 30 330043 PC Board 1 31 OO1023 Eye Bolt 4 32 NH061000 Nut M6 4 33 SN490200 Coun...

Reviews: