Troubleshooting JAT-630 Angle Drill

 

Any disassembly of the tool should be done by qualified service personnel. For problems not addressed 
below, contact JET technical service at 800-274-6846. 

Problem 

Possible cause 

Remedy 

Tool will not start. 

Air valve closed or obstructed. 

Open valve; clear any obstructions. 

Dirt or gum deposits on 
components. 

Flush tool with gum solvent. 
If problem persists, disassemble, 
clean and lubricate internal parts. 

Rotor vanes or other components 
are worn. 

Replace worn components. 
(Replace vanes as an entire set.) 

Trigger inoperable. 

Clean trigger mechanism to ensure 
free movement. Replace 
mechanism if needed. 

Bearing(s) worn. 

Disassemble and inspect bearing. 
Grease or replace as needed. 

Starts immediately when 
air is connected without 
throttle lever being 
pressed. 

Throttle lever malfunction. 

Clean throttle lever mechanism to 
ensure free movement. Replace 
mechanism if needed. 

Excessive or abnormal 
vibration. 

Bearings worn. 

Disassemble and inspect bearing. 
Grease or replace as needed. 

Loss of power; erratic 
action. 

Low air pressure. 

Verify compressor has proper CFM 
rating for tool. 
Check compressor regulator 
setting; set air pressure to 90 psi.   
Set regulator dial on tool to 
maximum setting. 
Check for loose connections.  

Moisture or obstruction in air 
hose. 

Air supply must be clean and dry. 
Clean out air hose(s) and remove 
any kinks or bends. 

Improper size of air transmission 
lines, hoses, fittings, or 
couplings. 

Use appropriate-sized air 
lines/hoses. 
Verify proper fittings/couplings. 

Dirt or gum deposits on 
components. 

Flush tool with gum solvent. 
Check and clean air filter on 
compressor.  
Clean external areas of tool. If 
problem persists, disassemble, 
clean and lubricate internal parts. 

Rotor vanes are worn. 

Replace vanes (entire set). 

Excessive heat develops 
in tool. 

Insufficient lubrication. 

Lubricate with air tool oil. 

Worn components. 

Replace components as needed. 

Severe air leakage. 
(Note: Minimal escape of 
air is often normal for air 
tools.) 

Air valve obstructed or damaged. 

Clean or replace. 

Housing loose or damaged. 

Tighten or replace as needed. 

Summary of Contents for 505630

Page 1: ...Pneumatic Angle Drill 505630 JAT 630 Operation Parts Manual M 505630 Edition 2 06 2015 JET 427 New Sanford Road LaVergne TN 37086 Ph 800 274 6848 www jettools com Copyright 2015 JET ...

Page 2: ...with any additional action needed JET has Authorized Service Centers located throughout the United States For the name of an Authorized Service Center in your area call 1 800 274 6846 or use the Service Center Locator on the JET website More Information JET is constantly adding new products For complete up to date product information check with your local distributor or visit the JET website How S...

Page 3: ...hromium from chemically treated lumber Your risk of exposure varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as face or dust masks that are specifically designed to filter out microscopic particles 9 Do not operate an air tool continually at full throttle without a work loa...

Page 4: ...y recommended accessories improper accessories may be hazardous 31 Maintain tools with care Keep air tool clean and oiled for best and safest performance 32 Do not use combustible gases carbon dioxide oxygen or any bottled gas as an air source for the tool These can present risk of explosion and serious injury 33 Do not lubricate the tool with combustible liquids such as kerosene diesel or jet fue...

Page 5: ... this document The instructions and warnings in this manual may not encompass all possible workplace environments The operator is expected to take appropriate precautions and exercise common sense As with any tool operation safety of operator and bystanders should be first priority If there are questions or comments please contact your local supplier or JET JET can also be reached at our web site ...

Page 6: ...ing Variable speed throttle lever Grip Inline Overall Length 8 in 203 2 mm Housing material Aluminum with rubber grip Net weight 2 78 lb 1 26 kg Shipping weight 3 18 lb 1 44 kg 1 The specified values are emission levels and are not necessarily to be seen as safe operating levels As workplace conditions vary this information is intended to allow the user to make a better estimation of the hazards a...

Page 7: ...hten chuck by hand while aligning bit Note Insert only the shank of a twist drill bit its flutes should remain free of the chuck jaws 5 Insert chuck key and rotate clockwise to fully tighten chuck 6 Select rotation direction with knob Figure 1 For reverse push knob into housing and turn it to keep it engaged For forward turn knob until it retracts from housing 7 Place bit against work item Grip dr...

Page 8: ...gular basis 6 Air line pressure may be increased accordingly to compensate for extra long air hoses usually over 25 feet Inside diameter of hose should be minimum 3 8 inch General Air Tool Information If the air tool is not performing according to specifications the following are among the most common causes See also Troubleshooting section Contaminated air such as a dirty air system or water in t...

Page 9: ... such as SAE 10 Many JET air tools have integral oil reservoirs which should be kept filled when in line oilers are not used If greasing is required use a grease that is highly water resistant for front case components on air impact wrenches grinders and sanders Recycling Protect the environment Your tool contains materials which can be recovered or recycled When its useful life has expired please...

Page 10: ...bnormal vibration Bearings worn Disassemble and inspect bearing Grease or replace as needed Loss of power erratic action Low air pressure Verify compressor has proper CFM rating for tool Check compressor regulator setting set air pressure to 90 psi Set regulator dial on tool to maximum setting Check for loose connections Moisture or obstruction in air hose Air supply must be clean and dry Clean ou...

Page 11: ...ollowing pages To order parts or reach our service department call 1 800 274 6848 Monday through Friday 8 00 a m to 5 00 p m CST Please have the stock number and serial number of your tool available when you call so that we may serve you quickly and accurately ...

Page 12: ...12 JAT 630 Pneumatic Angle Drill 505630 JAT 630 3 8 inch Angle Drill exploded view ...

Page 13: ...all bearing 6200Z 2 28 JAT630 28 Washer 1 29 56237 Oil cap 3 16in 1 30 JAT630 30 Pinion gear 1 Index Part No Description Qty 31 JAT630 31 Angle housing 1 32 JAT630 32 Spindle 1 33 JAT450 31 Wave washer WW 10 1 34 JAT630 34 Gear 1 35 JAT630 35 Retaining ring ISTW 10 1 36 JAT630 36 Key 1 37 JAT630 37 Bushing 1 38 JAT630 38 Retainer ring RTW 28 1 39 JAT620 27 Jacobs keyed chuck 3 8in 1 40 JAT630 40 S...