Jet 310016 Operation Manual Download Page 4

www.jetequipment.com

www.jetequipment.com

Measurement Operation:

(

1

)  Hold the meter and point it towards the surface to be measured.

(

2

)  Press and hold the Measurement Trigger to turn the meter ON. LCD will show a reading. If there is NO display  

  or reading, the battery may have depleted. Replace the battery and try again. 
(

3

)  Push the Laser select button while pressing and holding the Measurement Trigger to turn ON the laser beam.  

  Laser icon will appear on LCD above temperature. Aim the red laser beam approximately 1/2” above the point  
  of test. (

Note:

 pressing the Laser select button again turns the laser beam OFF). 

(

4

)  Select the unit of temperature (°C or °F) by first pressing and holding Measurement Trigger and then  using  

  °C select button or °F select button.  
(

5

)  Press the Backlight button to turn ON the LCD backlighting function.

(

6

)  Release the Trigger and the HOLD display icon will appear on the LCD indicating that the reading is being held.

(

7

)  The meter turns OFF automatically 7 seconds (app.) after Measurement Trigger is released. 

Measurement Considerations: 

Holding the meter by its handle, point the Infrared (IR) sensor towards the object whose temperature is to be  
measured. The meter automatically compensates for temperature deviations from ambient temperature. Keep  
in mind that it will take up to 30 minutes to adjust to a wider range of ambient temperatures. 

Battery Replacement:

When battery power is not sufficient, LCD will display.        You will need a new 9V battery. 

Notes: 
How it works

Infrared thermometers measure the surface temperature of an object. Meter’s optics sense the energy emitted, 
reflected or transmitted from an object and collects and focuses onto a detector. The electronics then translate the 
information into a temperature reading, which is displayed on the LCD. In thermometers with a laser beam, it is  
used for aiming purposes only.

Field of view

Make sure that the target is larger than the meter’s spot size. The smaller the target, the closer you should be to it. 
When accuracy is critical, make sure the target is at least twice as large as the spot size. 

4

4

Util

isa

tio

n :

(

1

) P

oint

ez l

e th

erm

om

ètre

 ve

rs l

a su

rfac

e à 

être

 m

esu

rée

.

(

2

) A

ppu

yez

 su

r la

 gâ

che

tte 

pou

r m

ettr

e l’a

ppa

reil

 so

us t

ens

ion

. L’

écr

an 

ACL

 aff

ich

e u

ne d

onn

ée. 

Si a

ucu

ne d

onn

ée  

 

 

n’es

t af

fich

ée, 

la p

ile 

peu

t d

evo

ir ê

tre 

rem

plac

ée. 

Rem

plac

ez l

a p

ile 

et e

ssa

yez

 de

 no

uve

au.

 

(

3

) A

ppu

yez

 su

r le

 bo

uto

n La

ser

 to

ut e

n te

nan

t la

 gâ

che

tte 

enfo

ncé

e p

our

 ac

tive

r le

 las

er. 

L ’icô

ne L

ase

r ap

para

ît s

ur l

’éc

ran

  

 

au-

des

sus

 de

 la 

tem

pér

atur

e. D

irig

ez l

e fa

isc

eau

 las

er à

 en

viro

n 1

/2 

po 

au-

des

sus

 du

 po

int 

de m

esu

re. 

 

 

Rem

arq

ue:

 si 

vou

s ap

puy

ez d

e n

ouv

eau

 su

r le

 bo

uto

n La

ser,

 le 

las

er s

’éte

int.

 

(

4

) S

élec

tion

nez

 l’u

nité

 de

 m

esu

re (

°C 

ou 

°F)

 en

 ten

ant 

la g

âch

ette

 de

 m

esu

re e

nfo

ncé

e et

 en

 sé

lec

tion

nan

t le

 bo

uto

n °C

 ou

 °F

.  

(

5

) A

ppu

yez

 su

r le

 bo

uto

n d

e ré

tro

écla

irag

e p

our

 ac

tive

r ce

tte 

fon

ctio

n.

(

6

) L

orsq

ue l

a g

âch

ette

 es

t re

lâc

hée

, l’i

côn

e H

OLD

 ap

para

ît à

 l’é

cran

 po

ur i

ndi

que

r q

ue l

a m

esu

re e

st s

auv

ega

rdé

e.

(

7

) L

e th

erm

om

ètre

 s’é

tein

t au

tom

atiq

uem

ent 

env

iro

n 7

 se

con

des

 un

e fo

is l

a g

âch

ette

 rel

âch

ée.

Pris

e d

e m

esu

res

:

En 

ten

ant 

l’ap

pare

il p

ar l

e m

anc

he, 

poin

tez

 le 

cap

teu

r à 

infr

aro

uge

 ve

rs l

e p

oint

 où

 la 

tem

pér

atur

e d

oit ê

tre 

rele

vée

. Le

 the

rm

o-

mètr

e co

mpe

nse

 au

tom

atiq

uem

ent 

les

 dé

viat

ion

s ca

usé

es p

ar l

a te

mpé

ratu

re a

mbi

ante

. R

app

elez

-vo

us q

ue c

ela 

peu

t p

ren

dre 

jus

qu’

à 3

0 m

inu

tes

 po

ur c

om

pen

ser

 un

e p

lus

 gr

and

e p

lag

e d

e te

mpé

ratu

res

 am

bian

tes

Rem

pla

cem

ent

 de

 la

 pi

le:

Lors

que

 la 

pile

 es

t fa

ibl

e, l’

écr

an 

ACL

 aff

ich

e.

 Vo

us d

eve

z in

stal

ler

 un

e n

ouv

elle

 pi

le d

e 9

 V. 

Rem

arq

ues

Fon

ctio

nne

men

t

Le t

her

mom

ètre

 à i

nfra

rou

ge m

esu

re l

a te

mpé

ratu

re d

e su

rfac

e d

’un

 ob

jet.

 Le

 ca

pteu

r d

e l’a

ppa

reil

 dé

tec

te l

’én

erg

ie é

mise

réfl

éch

ie o

u tr

ans

mise

 pa

r l’o

bjet

. Le

s in

for

mati

ons

 so

nt e

nsu

ite 

con

ver

ties

 en

 un

e m

esu

re d

e te

mpé

ratu

re q

ui e

st a

ffic

hée

 à 

l’éc

ran

. Le

 las

er d

’un

 the

rm

om

ètre

 es

t u

tilis

é p

our

 fac

ilite

r la

 vis

ée d

u ca

pteu

r.

Cha

mp 

de 

vis

ion

Ass

urez

-vo

us q

ue l

a ci

ble 

est 

plus

 gr

and

e q

ue l

a d

im

ens

ion

 du

 fai

sce

au.

 Pl

us l

a ci

ble 

est 

peti

te, 

plus

 le 

the

rm

om

ètre

 do

it e

n  

être

 pr

ès. 

Si u

ne t

rès

 gr

and

e p

réc

isio

n es

t ex

igé

e, a

ssu

rez

-vo

us q

ue l

a ci

ble 

est 

au 

moin

s d

eux

 fo

is p

lus

 gr

and

e q

ue l

a  

dim

ens

ion

 du

 fai

sce

au.

 

Reviews: