background image

 

Note: make sure the bag is fastened 
securely so that no dust will escape 
during operation. 

 

 

 

Attach the hose: 

Use one hose clamp (Q) to connect 
the hose (I) to the intake port. 

 

Fig 10 

Use the other hose clamp on the 
machine to be connected. 

 

5.2 Dust connection 

Connect the steel wire of the hose to 
the green-yellow ground wire (PE, Fig 
10). This eliminates electrostatic 
charging.  

Any hose or ductwork you use to 
connect the tool to the dust collector 
must be grounded , for avoiding 
explosion. 
( Dust Collector Grounding Kit, 
Article Number: JW1053). 

 

5.3 Mains connection 

Mains connection and any extension 
cords used must comply with 
applicable regulations. 
The mains voltage must comply with 
the information on the machine licence 
plate.  

The mains connection must have a  
10 A surge-proof fuse. 

Only use power cords marked H07RN-

Connections and repairs to the 
electrical equipment may only be 
carried out by qualified electricians.  

 

6.  Machine operation 

You can start and stop the machine 
with the ON/OFF switch (K). 

Fig 11 

The Switch has a removable safety 
key (R). When the key is not inserted 
the switch is locked in the OFF 
position.  

 

7. Maintenance and inspection 

General notes: 
Maintenance, cleaning and repair 
work may only be carried out after 
the machine is protected against 
accidental starting by pulling the 
mains plug. 

Inspect the proper function of the dust 
collection system daily. 

Clean the unit regularly. 

Defective safety devices must be 
replaced immediately. 

Repair and maintenance work on the 
electrical system may only be carried 
out by a qualified electrician. 

 

7.1 Cleaning filter bag 

Shake the filter bag whenever it is 
clogged and before each collector bag 
change. 

During the cleaning of the filter bag 

it’s 

necessary to use a mask (mask with 
filtration). 

 

7.2 Changing collector bag 

Always disconnect the dust collector 
from the power source (unplug) before 
servicing or changing filter. 

During the changing or cleaning of the 
collector bag it’s necessary to use a 
mask (mask with filtration). 

 

 

8. Trouble shooting 

 

Unit 

doesn’t start 

*No electricity- 
check mains and fuse. 

*Defective switch, motor or cord- 
consult an electrician. 

 

Air flow too weak 

*

Clogged filter- 

Clean filter. 

 

9. Environmental protection 

Protect the environment. 

Your appliance contains valuable 
materials which can be recovered or 
recycled. Please leave it at a 
specialized institution. 

 

This symbol indicates separate 
collection for electrical and electronic 
equipment required under the WEEE 
Directive (Directive 2012/19/EC) and is 
effective only within the European 
Union. 

10. Available accessories 

Stock number 10000315 

PVC-hose transparent, 

Ø100mm, 

length 2,5m 

Stock number JW1022

 

Hose clamp 

Ø100mm 

Stock number JW1053 

Dust collector grounding kit 

Stock number 10000339 

Automatic start unit 230V 

Further dust collection accessories 
available, see price list. 

Summary of Contents for 10001051M

Page 1: ...Original GB Operating Instructions Translations D Gebrauchsanleitung F Mode d emploi JPW Tool AG Tämperlistrasse 5 CH 8117 Fällanden Switzerland Phone 41 44 806 47 48 Fax 41 44 806 47 58 www jettools com M 10001051M 2015 04 ...

Page 2: ...ive 2004 108 EC EMC Directive Electro Magnetic Compatibility 2006 95 EC Low Voltage Directive 2011 65 EU RoHS Directive Reduction of Hazardous Substances designed in consideration of the standards EN ISO 12100 1 EN ISO 12100 2 EN ISO 13857 EN 349 EN 953 EN 60204 1 EN ISO 11202 EN 55014 1 EN55014 2 EN ISO 14121 1 Technical file compiled by Alain Schmid JPW TOOL AG General Manager 2015 04 17 Alain S...

Page 3: ... in the General Terms and Conditions GTC The GTC can be viewed at www jettools com or can be sent by post upon request The Seller reserves the right to make changes to the product and accessories at any time 3 Safety 3 1 Authorized use This dust collector is designed for sucking wood dust only Any other application is not permitted and may be carried out in specific cases only after consulting wit...

Page 4: ...maged power cord can lead to injuries caused by electricity Danger of explosion if not properly grounded 4 Machine specifications 4 1 Technical data Dust inlet Ø100mm Air flow 900 m h Vacuum pressure 1050Pa Collector bag capacity 55L Overall LxWxH 1555x815x380mm Net weight 19 kg Mains 230V 50Hz Motor power 550W Reference current 2 7 A Extension cord H07RN F 3x1 5mm Installation fuse protection 10A...

Page 5: ...Locate the motor side A Fig 6 and the bag side B of the base Note the holes for the legs of the bag side B are closer to the casters Fig 6 Attach with short bolts washers and nuts Attach filter bag hanger Attach filter gag hanger M with short bolts washers and nuts Fig 7 Install the filter bag Attach the loop of the filter bag to the filter bag hanger M Place the filter bag A over the bag support ...

Page 6: ...lug Inspect the proper function of the dust collection system daily Clean the unit regularly Defective safety devices must be replaced immediately Repair and maintenance work on the electrical system may only be carried out by a qualified electrician 7 1 Cleaning filter bag Shake the filter bag whenever it is clogged and before each collector bag change During the cleaning of the filter bag it s n...

Reviews: