14
3D3 – FILTERS CLEANING
1-
Turn OFF the machine by pressing button
“A” On/Off.
2-
Manually remove the overflow and
filters.
(Fig.25)
Fig.25
3-
Wash and clean filters thoroughly with
fresh running
water.
4-
Reposition all filters and components
inside the machine.
3D4 – EXTERNAL SURFACES CLEANING
Before carrying out any cleaning operations,
turn off the power at the mains.
To reduce the emission of pollutants into
the
enviro
n
ment,
clean
the
appliance
externally and where necessary
internally with products having a
biodegradability of over 90%.
WARNING!
CLEAN STAINLESS STEEL SURFACES BY
USING WARM SOAPY WATER; NEVER USE
DETERGENT
CONTAINING
ABRASIVE
SUBSTANCES
NOR
STEEL
SCRAPERS, COMMON
WIRE
WOOL,
OR
BRUSHES
.
RINSE
THOROUGHLY
USING A WET CLOTH AND
CAREFULLY
WIPE
DRY.
DO
NOT WASH
THE
APPLIANCE BY USING HIGH PRESSURE
WATER JETS.
3D5 – TURNING OFF THE MACHINE
1-
Completely drain the water from the tank.
(see par.3D1/2/3)
2-
Turn OFF the machine by pressing button
“A” On/Off.
3-
Close the door and turn off the power at
the mains.
3E – WARNING MESSAGES
DISPLAYED ON THE CONTROL
PANEL
N.B.
If the machine is in
the
OFF mode,
warning messages will not be
visualized on the display. Turn ON the
machine to visualize
the
error
type
.
The following warning messages are
visualized on the display:
ALR 1 - WATER FILL
Water fill not completed during the available
maximum time (10min).
Verify
that
the
water
supply
is
correctly
connected, open and free of obstructions.
Verify that solenoid valve filter is free
of obstructions and deposit
s
.
Verify that water supply pressure is
adequate (par.1D – Technical Data).
Verify that machine’s door is
completely closed and the overflow device
is correctly positioned inside the tank.
N.B.
If water fill timing expires or water
level signal is not
responded to
,
the
solenoid valve is automatically
interrupted. To restart solenoid valve
press any button on the control panel.
ALR 2 - DRAIN ANOMALY
Drainage not completed on the
maximum programmed timing
.
Verify that
the
overflow
device
is
completely removed and no obstructions
are present in the water drain line.
ACTIONS AFTER MACHINE ERROR
:
Booster
and
tank
heating
elements
are interrupted, water load is deactivated,
control panel display visualizes the error
and
the electronic card is
de
activated.
All LED buttons are OFF. Washing cycle
is inter
r
upted (stan
d
by mode) and restored
if
the problem is solved. It is always possible
to turn OFF the machine by pressing
button “A”
ON/OFF,
and
if
the
problem is solved,
the
warning messages
will
no longer
be