Connection
Connector
Housing
Cable
d
External switch-
off
3.5 mm jack
plug
Socket
a b
2.5 m 3-wire (cable included in delivery)
a
Input (+)
RD (red)
b
Ground (GND)
BK (black) / WH (white)
M12 x 1,
A coded
(optional)
Plug
1 = input (+)
BN (brown)
2 = ground (GND) WH (white)
e
Level input
3.5 mm jack
plug
Socket
ab c
Manufacturer's accessories
a
Main alarm
RD (red)
b
Pre-alarm
WH (white)
c
Ground (GND)
BK (black)
M12 x 1,
A coded
(optional)
Plug
1 = pre-alarm
BN (brown)
2 = main alarm
WH (white)
3 = ground (GND) BU (blue)
f
External control
RCA
Socket
a b
1.5 m 2-wire (cable included in delivery)
a
Input (+)
BN (brown)
b
Ground (GND)
WH (white)
CSA version
Plug
1.5 m, 3-wire (cable included in delivery)
1 = input (+)
BN (brown)
2 = -
BK (black)
3 = ground (GND) BU (blue)
M12 x 1,
B coded
(optional)
Plug
1 = ground (GND) BN (brown)
2 = pulses
WH (white)
3 = pulses
BU (blue)
4 = ground (GND) BK (black)
NOTICE!
The protection class of the control unit is only ensured if the connection ports are protected by caps or the
standard connectors are inserted.
Operation | Operation & Maintenance Instructions |
27