11.1.1 Replacing diaphragm, MAGDOS DE/DX 20...100
①
Dosing head with valves
②
Diaphragm
③
Support plate (only on DE/DX 20)
④
Deflector plate
⑤
Diaphragm flange
⑥
Diaphragm rod
⑦
Compression spring
⑧
Drive unit
CAUTION!
Chemical may spray out. This may lead to chemical or other burns. The dosing pump must always be
depressurised and rinsed with water or a suitable medium before starting any work on the dosing pump.
1
2
3
4
5
6
①
②
③
④
⑤
⑥
⑦
⑧
24