INSTALLING DL-AC-FLEX-HW
$&)OH[LEOH/LQHDU6WULS
TURN OFF ELECTRICITY
DWPDLQIXVHER[RUFLUFXLWEUHDNHUER[EHIRUH
beginning installation by switching circuit breaker
off or removing fuse.
0,1&6833/<&21'8&7256
HARDWARE FOR INSTALLATION
(NOT INCLUDED)
HARDWARE
(INCLUDED)
,1'((3%2;
0,1µ'(37+
6-7&25'675$,15(/,()%86+,1*
Single Use Parts
Permanently locks on SJT cord.
0DNHVXUHWRGRXEOHFKHFN
length before locking bushing
on cord.
Any attempt to remove the
bushing will destroy the part.
WIRE NUTS
02817,1*
SCREWS
CONSULT A QUALIFIED ELECTRICIAN TO
ENSURE CORRECT BRANCH CIRCUIT
ON OFF
1
TURN OFF ELECTRICITY
AT MAIN FUSE BOX
$&)/(;,1387&$%/(
SURGE SUPPRESSOR
287387&$%/(
$&)/(;,1387&$%/(
SURGE SUPPRESSOR
,1387&$%/(
(120V AC Input)
SURGE SUPPRESSOR
287387&$%/(
:+,7(+27
%/$&.1(875$/
167V DC Output
SURGE SUPPRESSOR
INPUT WIRES
'28%/('
+2/(
02817,1*
SCREWS
685*(6835(6625287387&$%/(
SURGE SUPPRES
,HDWVLQN3ODWH
6833/<:,5(6
%/$&.+27
:+,7(1(875$/
GREEN or COPPER (GROUND)
%/$&.+27
:+,7(1(875$/
GREEN (GROUND)
&211(&7685*(68335(6625,1387:,5(6:,7+6833/<:,5(6
1. Connect Supply Wires to SURGE SUPPRESSOR input wires: BLACK TO BLACK AND WHITE TO WHITE,
and green or copper to green.
2. Secure all connections with wire nuts (not included).
3. Determine length needed outside of integral heatsink plate, secure included SJT cord strain relief
RQWR$&)/(;LQSXWFDEOHZLWKDSDLURISOLHUVDQGSXVKLWLQWRLQWHJUDOKHDWLQNSODWH·V'28%/('
hole.
OPTIONAL:
WRVKRUWHQ$&)/(;LQSXWFDEOHPHDVXUHDQGFXW$&)/(;LQSXWFDEOHWRGHVLUHGOHQJWK
DQGUHFRQQHFW$&)/(;LQSXWFDEOHZLWK685*(68335(6625RXWSXWFDEOH
BLACK TO BLACK AND
WHITE TO WHITE inside of heatsink coverplate, secure connection with wire nuts (not included).
5.
&DUHIXOO\WXFNDOOFRQQHFWHGZLUHVLQVLGHWKHMXQFWLRQER[6HFXUHLQWHJUDOKHDWVLQNFRYHUSODWH
WRMXQFWLRQER[ZLWKPRXQWLQJVFUHZVQRWLQFOXGHGPDNLQJVXUHWRQRWSLQFKDQ\ZLUHVRUZLUH
nuts.
SJT Cord Strain Relief
NOT FOR OUTDOOR INSTALLATION
*DO NOT REMOVE SURGE SUPPRESSOR FROM INTEGRAL HEATSINK COVERPLATE.
Doing so is in direct violation to UL requirements and will void the warranty of the product.
INCORRECT BRANCH CIRCUIT CONNECTION
WILL VOID THE WARRANTY OF THE PRODUCT.
A
RATED 120VOLT AC | 4.95Watt / Foot
$&)/(;,1387&$%/(
&RQQHFWVWR685*(68335(6625287387&$%/(
%/$&.WR%/$&.
:+,7(WR:+,7(