![Jesco FEDOS DX 17 Operating Manual Download Page 24](http://html1.mh-extra.com/html/jesco/fedos-dx-17/fedos-dx-17_operating-manual_644925024.webp)
Connection
Connector
Housing
Cable
d
External
shut-off
3.5 mm jack
plug
Socket
a b
2.5 m 3-wire (cable included in delivery)
a
Input (+)
RD (red)
b
Ground (GND)
BK (black) / WH (white)
M12 x 1,
A coded
(optional)
Plug
1 = input (+)
BN (brown)
2 = ground (GND) WH (white)
e
Level input
3.5 mm jack
plug
Socket
ab c
Manufacturer's accessories
a
Main alarm
RD (red)
b
Low level alert WH (white)
c
Ground (GND)
BK (black)
M12 x 1,
A coded
(optional)
Plug
1 = low level
alert
BN (brown)
2 = main alarm
WH (white)
3 = ground (GND) BU (blue)
f
External control
RCA
Socket
a b
1.5 m 2-wire (cable included in delivery)
a
Input (+)
BN (brown)
b
Ground (GND)
WH (white)
CSA version
Plug
1.5 m, 3-wire (cable included in delivery)
1 = input (+)
BN (brown)
2 = -
BK (black)
3 = ground (GND) BU (blue)
M12 x 1,
B coded
(optional)
Plug
1 = ground (GND) BN (brown)
2 = pulses
WH (white)
3 = pulses
BU (blue)
4 = ground (GND) BK (black)
NOTE!
The protection class of the control unit is only ensured if the connection ports are protected by caps or the
standard connectors are inserted.
24
| Operating Manual FEDOS E/DX | Operation