Declaration of conformity

This declaration is no assurance of characteristics in the sense of the product liability law. The safety notes
in the operation & maintenance instructions must be obeyed.

EC – Declaration of Conformity

We,

Lutz-Jesco GmbH

Am Bostelberge 19
D – 30900 Wedemark

hereby certify
that the product described in the following complies with the relevant fundamental
safety and sanitary requirements and the EC regulations mentioned below due to the
concept and design of the version sold by us.
If the product is modified without our consent, this declaration loses its validity.

Product description:

Perestaltic Pump

Model designation:

EASYDOS Peristaltic V

Relevant EC regulations:

EC Low-Voltage Directive (73/23/EEC)
EC Electromagnetic Compatibility Directive
(93/68/EEC)

Applied harmonized

EN 292-1 and EN 292-2,Safety of Machines

standards, especially:

EN 50081 Parts 1 and 2, EN 50082 Parts 1 and 2,
Electromagnetic Compatibility, Emission of Noise
and Noise Immunity

Applied national standards

VDE 0700, Teil 1

and technical specifications,
especially:

Date, Signature of Manufacturer: 2005/05/01 . . . . . . . . . . . . . . . . . . . . . . . . . .

Information on the signer:

Mr. Lucjan Gogolin, Head of Technical Office

This declaration is no assurance of characteristics in the sens of the product liability law.
The safety notes in the operating instructions must be observed.

Summary of Contents for EASYDOS Peristaltic V

Page 1: ...nance Instruction Maintenance Instruction Maintenance Instruction Maintenance Instruction Maintenance Instruction Read these operation maintenance instructions before start up To be held for future re...

Page 2: ...f operation 9 Mode of operation 1 adjustable rate of delivery 9 Mode of operation 2 one or two time relays 10 Mode of operation 3 1 time relay with adjustable rate of delivery on channel 1 12 Mode of...

Page 3: ...azardous situation Non compliance can lead to death or serious injury CAUTION Refers to a potentially hazardous situation Non compliance can lead to minor injury or property damage NOTICE Appears in c...

Page 4: ...1 Potentiometer P1q Q Potentiometer P2 Error signal L3 case fixing screw 6 Table with jumper positions Pump housing 7 Rotor Pump tube Inner electronic cover 10 Cover of electronic removed End splices...

Page 5: ...table between 7 ml h and 400 ml h due to the high torque capabilities of the DC motor applicable even for smallest capacities against pressure of up to 2 bar 29 psig or 10 m 32 8 ft water column or vi...

Page 6: ...level of the barrel or supply tank containing the product Pump must be installed vertically with tube connections facing downward CAUTION The pump must not be used for inflammable products When pumpi...

Page 7: ...rminal block arrangement in the upper part of the installation housing Fasten union nut of the threaded cable gland A high IP Protection class is only achieved in this way Place device on installation...

Page 8: ...re on the right side If another mode of operation is required pull jumper upwards with a forceps and put it onto the pin couple that corresponds to the desired mode of operation Mode of operation 1 ad...

Page 9: ...inals 9 and 10 may be added NOTICE If no suction pipe with float switch is installed terminals 11 and 12 must be jumped With active control voltage on terminal 4 In2 terminals 5 neutral and 6 phase ar...

Page 10: ...he warning signal are designated A jumper must be set that the pin marked with B and the pin in the middle are connected In this operation mode the operation time is started with an impulse that last...

Page 11: ...ect selection selector switch SW in position 2 can be set With potentiometer P2 the rotor speed may be adjusted to a rate of delivery between 0 1 and 2 ml min With a control voltage 230 V AC at termin...

Page 12: ...ter P2 the rotor speed can be set to operate at a rate of delivery between 0 1 and 2 ml min As long as the control current 230 V AC at terminal 4 is active the pump operates at the adjusted rate of de...

Page 13: ...which can be done during normal service NOTICE Before installing the EASYDOS Perestaltic V the chemical compatibility of the tube and the process fluid has to be evaluated The life span of the pump t...

Page 14: ...ys disconnected from the power supply while exchanging the tube switch off power supply of the chemical feed system The pump housing is a wearing part and must be changed after reasonable periods of t...

Page 15: ...his declaration loses its validity Product description Perestaltic Pump Model designation EASYDOS Peristaltic V Relevant EC regulations EC Low Voltage Directive 73 23 EEC EC Electromagnetic Compatibil...

Page 16: ...g Yes No Corrosive Yes No We hereby certify that the product has been cleaned thoroughly inside and outside before returning that it is free from hazardous material i e chemical biological toxic flamm...

Page 17: ...ical fault p Premature wear p Connections plug connectors or cables loose p Wear parts p Operating elements e g switches push buttons p Breakage other damage p Electronic unit p Corrosion p Damage in...

Page 18: ......

Page 19: ......

Page 20: ...180 497516 E Mail info lutz jesco nl Internet www lutz jesco nl USA Lutz JESCO America Corp 55 Bermar Park Rochester N Y 14624 USA Phone 1 585 426 0990 Fax 1 585 426 4025 E Mail mail jescoamerica com...

Reviews: