background image

 

 

2 of 3 

 

 

 

 

 

 

 

 

 

 

          

    

 

Figure 1 

5)

 

If the cable will not reach the power supply, 
contact your local representative for the 
required extension cable. 

CAUTION: Verify that the area is free of 
flammables.

 

6)

 

Replace the cover on the power supply 
housing.

 

7)

 

Switch “ON” the power supply making sure 
the Illuminator is functioning properly, with 
all LED’s illuminated. 

8)

 

If the LED’s do not illuminate, remove the 
cover on the power supply once the power as 
been turned on.  An LED will be lit if it is 
wired correctly.  See Figure 2, Detail “A” 

9)

 

If the LED in the power supply is not lit, 
check the power source and the connection 
before continuing. 

Any additional components must be installed prior 
to the customer’s sealing fitting. 

FUSE REPLACEMENT 

 

This power supply is fused for AC protection. 

In the event of a large voltage surge, the fuse may 
release, causing no output voltage.  Replace the fuse 
with Clark-Reliance P/N E-F-DIN-F400MA only.  
(See figure 2) 

 

 

OPERATION 

 

The LED illuminator can run continuously.  

The operating life of LED lights exceed 100,000 
hours under normal conditions. 

ROUTINE MAINTENANCE 

 

Keep window on the front of the light clean 

using commercial glass cleaners, such as Windex 

® 

or similar.  Never use harsh abrasives, wire brushes, 
metal scrapers, or any material that could scratch 
the window.  The window may be cleaned while the 
unit is in operation. 

 

The light may be removed while the unit is in 

operation during inspection or maintenance of the 
customer’s gage glass.  The Illuminator may also be 
disconnected from the power supply, if desired.  
Disconnect the cord at the supplied screw connector 
adjacent to the power supply.  The plant power 
going to the power supply does not need to be 
disconnected. 

 

SPECIFICATIONS 

 Power Supply:   

120 or 240 VAC @ 50-60 Hz 

 Power   

 

< 750 mA @ 120 VAC 

 Consumption:   

< 375 mA @ 240 VAC 

 
 Est. Life: 

 

100,000 Hours (continuous) 

 
 Agency Approvals: 

FM Approved, CSA 

 

 

 

Class I, Div. I Grps. B, C, & D

 

 

 

Class II, Div I, Grps. E, F, & G

 

 

 

 

 Wire Size: 

 

Min 18 AWG / Max 12 AWG 

 Max dist. from   

 

 power supply to light: 

50 feet (15M) 

 
 Ambient Temperature: 

-40 F (-40 C) to 170 F (77 C) 

 Electrical Connection: 

¾” FNPT 

 

NORTHEAST CONTROLS INCORPORATED

TEL: 201-327-7660 | FAX: 201-327-3242

www.nciweb.com

NORTHEAST CONTROLS INCORPORATED

TEL: 201-327-7660 | FAX: 201-327-3242