The warranty of Jereh electrostatic spray disinfection equipment is implemented
from the date of purchase. The warranty terms are as follows:
Warranty Policy
During the warranty period (calculated from the date of invoice date), Jereh
provides warranty service, if the product fails during normal use Please note the
following:
Basic Statement
This warranty certificate will not be reissued if lost, please keep it properly.
This warranty certificate is valid only in the Republic of China (Hong Kong / Macau
/ Taiwan is temporarily unavailable).
Jereh does not provide on-site services for overseas customers (outside mainland
China). For damages during the warranty period, Jereh will provide replacements
for free; for damages caused by natural or human factors beyond the warranty
period, Jereh will provide paid replacements, and the freight and custom duty
shall be paid by the customers.
•
•
•
During the warranty period, the following conditions are not covered by the free
warranty:
Product warranty (
For domestic customers
)
Free warranty for the device and main components (Air compressor, spray gun) is
one year.
Consumables are provided in accordance with the relevant provisions.
•
•
•
10/11
Troubleshooting Guide
Air fittings are loose.
Air fittings are too tight and
the gasket or seal is crushed
and damaged.
The component connected
to the nozzle is loose.
Check if the black hose on
the rear of the nozzle is
pulled and reconnected.
Test spray charge with the
multimeter. If there are
charges, the bulb needs to
be replaced.
Check the built-in filter
screen of liquid bottle to see
if any jam exists, replace it if
necessary.
Check for damaged wires
and replace if necessary.
The position of the bottle is
too high compared to the
nozzle, and the water
pressure is not enough.
Raise the bottle to reduce the
height difference between
the nozzle and the bottle.
Check for leaks in
components. Apply soapy
water to air connections –
tighten ones that bubble.
Check the air assembly for
damage and replace
damaged seals.
Fasten loose connection
hoses.
The hose connection is not
reliable.
Check for leaking trachea
and replace it.
Clean nozzle according to
instructions.
The hose is worn or has an
opening.
Nozzle is blocked.
low liquid level in the bottle.
Refill bottle.
Trigger is disengaged.
Light bulb damaged.
Damaged wire.
Clogged liquid Filter.
Make sure trigger is engaged.
Air pressure
of spray
appears low
The spray
from nozzle is
erratic
Charging
indicator
(LED) is out
The nozzle
fluid flow is
low
Symptom
Possible Problem(s)
Corrective Action