12
Specifications
Function
Range
Resolutio
n
Accuracy
DC Voltage
600mV
0.1mV
(1.0% r 3 digits)
6V
0.001V
60V
0.01V
600V
0.1V
1000V
1V
(1.0% r 5 digits)
AC Voltage
45Hz to 60Hz
6V
0.001V
(1.0% r 3 digits)
60V
0.01V
600V
0.1V
1000V
1V
(1.5% r 5 digits)
All AC voltage ranges are specified from 5% of range to 100% of range
DC Current
600
A
0.1
A
(1.0% r 3 digits)
6000
A
1
A
60mA
0.01mA
600mA
0.1mA
6A
0.001A
(1.5% r 3 digits)
10A
0.01A
(10A: 30 sec max with reduced accuracy)
AC Current
45Hz to 60Hz
600
A
0.1
A
(1.5% r 3 digits)
6000
A
1
A
60mA
0.01mA
600mA
0.1mA
6A
0.001A
(2.0% r 5 digits)
10A
0.01A
(10A: 30 sec max with reduced accuracy)
All AC voltage ranges are specified from 5% of range to 100% of range
NOTE:
Accuracy is stated at 65
o
F to 83
o
F (18
o
C to 28
o
C) and less than 75% RH.