background image

12

Electronic Ignition System

Initial lighting and gas flame adjustments

This cooktop is equipped for electronic auto-reignition by means 
of a spark igniter located at the rear of each burner. The burners 
are designed to light at any valve rotation that admits sufficient 
gas flow to support a flame and to automatically relight following a 
loss of flame due to a draft or other adverse condition. This 
feature is provided only as a convenience.

Check Operation of Surface Burners

Push in and turn the surface burners control knobs to light. 
The surface burner flame should light within 4 seconds. The first 
time a surface burner is lighted it may take longer that 4 seconds 
to light because of air in the gas line. 
Check the flame on “HIGH” for a blue color. It should be clean and 
soft in character. No yellow tip, blowing or lifting of flame should 
occur. Occasional orange flashes are normal and reflect different 
elements in the air or gas.
After verifying the proper burner operation, turn the control knobs 
to “OFF.”
If burners do not light properly:

Turn surface burner control knob to the “OFF” position. 

Check that the power supply cord is plugged in and the circuit 
breaker has not tripped or the fuse blown. 

Check that the gas shutoff valves are set to the “open” 
position. 

Check that burner caps are properly positioned on burner 
bases.

Recheck operation of surface burners. If a burner does not light at 
this point, contact your dealer or authorized service company for 
assistance.

Adjust Flame Height

Smart Port Burner System

This cooktop is equipped with a Smart Port Burner System. The 
Smart Port Burner System produces a small flame directly under 
each grate finger and a larger flame between each grate finger. 
The visual difference between the ports will be noticeable when 
the burner is used or when adjustments are made to the flame 
length. 
Adjust the height of top burner flames. The cooktop “low” burner 
flame should be a steady blue flame approximately ¼" (0.64 cm) 
high.

To adjust standard burners:

The flame can be adjusted using the adjustment screw in the 
center of the valve stem. The valve stem is located directly 
underneath the control knob.
If the “low” flame needs to be adjusted:

1. Light 1 burner and turn to lowest setting.
2. Remove the control knob.
3. Hold the knob stem in the low position using a pair of pliers. 

Use an

 ¹⁄₈

" (3.0 mm) flat-blade screwdriver to turn the screw 

located in the center of the control knob stem until the flame is 
the proper size.

4. Replace the control knob.
5. Test the flame by turning the control from “LO” to “HI,” 

checking the flame at each setting.

6. Repeat above steps for each burner.

Complete Installation

1. Check that all parts are now installed. If there is an extra part, 

go back through the steps to see which step was skipped.

2. Check that you have all your tools.
3. Dispose of/recycle all packaging materials.
4. Use a mild solution of liquid household cleaner and warm 

water to clean cooktop before use. Dry thoroughly with a soft 
cloth. For more information, see the “Cooktop Care” section 
of the Use and Care Guide.

5. Read “Cooktop Use” in the cooktop Use and Care Guide.
6. Reconnect power.
NOTE: If the cooktop does not work after turning on the power, 
check that a circuit breaker has not tripped or a household fuse 
has not blown. See “Troubleshooting” section in the Use and Care 
Guide for further information.
7. Use the Flow Tester Card provided with your cooktop to check 

the airflow (see card for step-by-step instructions).

If you need Assistance or Service:

Please reference the “Assistance or Service” section of the Use 
and Care Guide or contact the dealer from whom you purchased 
your cooktop.

A. Low flame
B. High flame

A

B

Summary of Contents for W10197058B

Page 1: ...e 21 Raccordement au gaz 22 Système d allumage électronique 24 Achever l installation 24 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and...

Page 2: ...upplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions In the State...

Page 3: ...um clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section The cooktop is designed to hang from the countertop by its side or rear flanges The gas and electric supply should be located as shown in Cabinet Dimensions section so that they are accessible without requiring removal of the co...

Page 4: ... H I C A B A B D C E F I G H A 30 76 2 cm on 30 76 2 cm models 36 91 4 cm on 36 91 4 cm models B Combustible area above countertop shown by dashed box above C 30 76 2 cm minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet 24 61 0 cm minimum clearance if bottom of wood or metal cabinet is covered by not less than 0 6 cm flame retardant millboard covered w...

Page 5: ...ed Elbows too close together can cause excess turbulence that reduces airflow Do not use a 5 12 7 cm elbow in a 6 15 2 cm or 3 x 10 8 3 x 25 4 cm system Do not reduce to a 5 12 7 cm system after using a 6 15 2 cm or 3 x 10 8 3 x 25 4 cm fittings Avoid forming handmade crimps Handmade crimps may restrict airflow Use a Jenn Air vent cap for proper performance If an alternate wall or roof cap is used...

Page 6: ...plete installation instructions For more information on the Jenn Air Duct Free Filter Accessory Kit contact your Jenn Air dealer or call 1 800 JENNAIR 1 800 536 6247 Option 1 Roof Venting Option 2 Wall Venting A Roof cap B 6 15 2 cm round roof venting A 6 15 2 cm round wall venting B Wall cap Option 3 Venting Between Floor Joist Option 4 Venting behind Cabinet Kick Plate A Wall cap B 6 15 2 cm rou...

Page 7: ...d Ohio 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this cooktop be provided Electronic ignition systems operate within wide voltage limits but proper grounding and polarity are necessary Check that the outlet provides 120 volt power and is correctly gr...

Page 8: ...teel tubing gas connector designed by CSA to connect the cooktop to the rigid gas supply line A male pipe thread is needed for connection to the female pipe threads of the inlet to the cooktop pressure regulator Do not kink or damage the flexible metal tubing when moving the cooktop Rigid pipe connection The rigid pipe connection requires a combination of pipe fittings to obtain an in line connect...

Page 9: ...lower Optional section 5 Using 2 or more people remove the cooktop from the carton REMEMBER An undercounter built in oven cannot be installed under this cooktop 6 Place cooktop right side up into the cutout NOTE Make sure that the front edge of the cooktop is parallel to the front edge of the countertop If repositioning is needed lift entire cooktop up from the cutout to avoid scratching the count...

Page 10: ...ollow steps 5 10 in the Install Cooktop section Make Gas Connection 1 Apply pipe joint compound made for use with Natural and LP gas to the smaller thread ends of the flexible connector adapters see C and G in the following illustration 2 Attach one adapter to the gas pressure regulator and the other adapter to the gas shutoff valve Tighten both adapters 3 Use a combination wrench and channel lock...

Page 11: ... leak Correct any leak found 3 Remove surface burner caps and grates from parts package Align notches in burner caps with pins in burner base Burner caps should be level when properly positioned If burner caps are not properly positioned surface burners will not light Place burner grates over burners and caps 4 Plug into a grounded 3 prong outlet A Manifold entrance B Gas pressure regulator C Use ...

Page 12: ...ifference between the ports will be noticeable when the burner is used or when adjustments are made to the flame length Adjust the height of top burner flames The cooktop low burner flame should be a steady blue flame approximately 0 64 cm high To adjust standard burners The flame can be adjusted using the adjustment screw in the center of the valve stem The valve stem is located directly undernea...

Page 13: ...t AVERTISSEMENT Si les renseignements dans ce manuel ne sont pas exactement observés un incendie ou une explosion peut survenir causant des dommages au produit des blessures ou un décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d ...

Page 14: ...table de cuisson doivent être scellées Respecter les dimensions indiquées pour les ouvertures à découper dans les placards Ces dimensions constituent les valeurs minimales des dégagements de séparation Une source d électricité avec liaison à la terre est nécessaire Voir la section Spécifications électriques Une source de gaz adéquate doit être disponible Voir la section Spécifications de l aliment...

Page 15: ...A240 ou des codes locaux en vigueur Dimensions du produit Table de cuisson de 30 76 2 cm Table de cuisson de 36 91 4 cm A 21 54 6 cm B 19 50 0 cm C Emplacement de la plaque signalétique A 30 76 2 cm B 12 32 9 cm entre l axe central de la table de cuisson et l axe central de la tubulure de distribution de gaz C 4 10 2 cm D 6 16 8 cm E 18 46 8 cm F Dégagement minimal recommandé de 1 4 3 cm entre le ...

Page 16: ... entre le dessus de la table de cuisson et le fond d un placard métallique ou de bois non couvert distance de séparation de 24 61 cm ou plus si le fond du placard de métal ou de bois est recouvert d une plaque d au moins 0 6 cm de matériau résistant aux flammes lui même recouvert d une feuille métallique d une épaisseur correspondant à un calibre de 28 au moins pour l acier 0 015 0 04 cm pour l ac...

Page 17: ... de chaque jointure du circuit d évacuation assurer l étanchéité avec les brides de serrage À l aide d un produit de calfeutrage assurer l étanchéité autour de la bouche de décharge à l extérieur à travers le mur ou le toit La longueur du système d évacuation et le nombre de coudes doit être réduit au minimum pour une performance efficace La longueur maximale équivalente du circuit d évacuation es...

Page 18: ...d un conduit flexible Un conduit flexible peut causer une rétro pression et des turbulences de l air ce qui réduit considérablement la performance A Bouche de décharge murale B Conduit métallique de dia 6 15 2 cm C 16 40 6 cm maximum D Conduit PVC pour égout de dia 6 15 2 cm E Conduit métallique de dia 6 15 2 cm F Raccord PVC de dia 6 15 2 cm G Dalle de béton H Conduit PVC pour égout de dia 6 15 2...

Page 19: ...et règlements locaux En l absence de code local l installation doit satisfaire aux prescriptions de la plus récente édition du code national américain en vigueur National Fuel Gas Code ANSI Z223 1 ou à la norme CAN CGA B149 IMPORTANT Les tests de fuite de la table de cuisson doivent être effectués selon les instructions du fabricant Type de gaz Gaz naturel La conception de cette table de cuisson a...

Page 20: ...site pas le démontage de la table de cuisson pour les manœuvres d ouverture fermeture Ne pas entraver l accès au robinet d arrêt manuel Le robinet d arrêt manuel est prévu pour ouvrir ou fermer l alimentation en gaz de la table de cuisson Détendeur de gaz Le détendeur fourni avec cette table de cuisson doit être utilisé La pression d alimentation du détendeur doit être comme suit pour un fonctionn...

Page 21: ...tes doivent être exécutées si le produit est installé avec une configuration d ébénisterie en péninsule ou en îlot La volute d évacuation est montée à l usine de manière à ce que le système d évacuation soit orienté directement vers l arrière du placard à travers un mur extérieur Pour faire pivoter le ventilateur 1 Repérer les 4 bouchons en plastique dans la dérivation de la chambre de distributio...

Page 22: ...our une utilisation avec du gaz naturel ou du gaz propane sur l extrémité filetée la plus petite des adaptateurs de raccord flexible voir C et G dans l illustration suivante 2 Fixer un raccord d adaptation sur le détendeur et l autre raccord d adaptation sur le robinet d arrêt de la canalisation de gaz Serrer les deux raccords d adaptation 3 Utiliser une clé mixte de et une pince multiprise pour f...

Page 23: ...et les grilles du sachet de pièces Aligner les encoches des chapeaux de brûleur avec les broches dans la base de chaque brûleur Un chapeau de brûleur correctement placé doit être horizontal Si le chapeau de brûleur n est pas correctement placé le brûleur de surface ne peut s allumer Placer les grilles de brûleur sur les brûleurs et chapeaux 4 Brancher sur une prise de courant à 3 alvéoles reliée à...

Page 24: ...n doit observer des flammes stables bleues d environ 0 64 cm Réglage des brûleurs standard La vis de réglage au centre de la tige de commande du robinet permet de régler la taille des flammes La tige de commande est située directement au dessous du bouton de commande S il est nécessaire de régler la taille des flammes pour le débit thermique minimum 1 Allumer 1 brûleur et le tourner au réglage le ...

Reviews: