Jenn-Air JXI8536DS0 Installation Instructions And Use & Care Manual Download Page 4

4

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Level

Drill with 1¼" (3.0 cm), 

³⁄₈

" (9.5 mm), 

⁷⁄₆₄

" (2.75 mm) and 

¹⁄₈

" (3.0 mm) drill bits

Pilot hole drill bits (determined by chimney support 
attachment method)

Pencil

Wire stripper or utility knife

Tape measure or ruler

Pliers

Caulking gun and weatherproof caulking compound

Vent clamps

Jigsaw or keyhole saw

Flat-blade screwdriver

Metal snips

Phillips screwdriver

Parts needed

Home power supply cable

½" (12.7 mm) UL listed or CSA approved strain reliefs (2)

UL listed wire connectors (3)

For vented installations, you will also need: 

Wall or roof cap

Metal vent system

For non-vented (recirculating) installations, you will also 
need:

Recirculating Kit Part Number W10692909 for non-vented 
(recirculating) installations only. See “Assistance or Service” 
section to order.

6" (15.2 cm) round metal vent duct. Length required is 
determined by ceiling height. 

Parts Supplied

Remove parts from packages. Check that all parts are included.

Hood canopy assembly with ventilator and LED light installed

Filter—installed in hood canopy

4.2 x 8 mm screws (60)

5 x 45 mm screws (4)

Mounting template

Upper vent covers (2)

Lower vent covers (2)

Vent transition with backdraft damper installed

3.5 x 9.5 mm mounting screws (2)

Plastic vent clips (4)

Upper horizontal support bracket

Horizontal support

Vertical supports (8)

3.5 x 6.5 mm screws (4)

2.9 x 3 mm screws (2)

T10

®

 Torx

®†

 adapter

T20

®

 Torx

®

 adapter

Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial/rating plate. The model/serial/rating 
plate is located behind the left filter on the rear wall of the vent 
hood.

Canopy hood location should be away from strong draft areas, 
such as windows, doors and strong heating vents. 

Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical 
Requirements” section.

Because of the size and weight of this island hood, the chimney 
support must be securely attached to the ceiling.

For plaster or drywall ceilings, the chimney support must be 
attached to joists. If this is not possible, you must build a 
support structure behind the plaster or drywall. The support 
structure must be able to support 100 lbs (45.4 kg).

This range hood is recommended for use with cooktops with a 
maximum total rating of 78,000 BTUs or less.
The range hood is factory set for venting through the roof.

For non-vented (recirculating) installation, see “Non-vented 
(recirculating) Installations” in “Assemble and Install Range 
Hood” section. Recirculation Kit Part Number W10692909 is 
available from your dealer or an authorized parts distributor. 

All openings in ceiling and wall where range hood will be installed 
must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local 
codes.

Product Dimensions

*Vented installations only

**Non-vented (recirculating) installations only

†®TORX, T10 and T20 are registered trademarks of Acument Intellectual Properties, LLC.

12

¹⁄₄

"

 

(31.0 cm)

13

³⁄₁₆

"

(33.5 cm)

36" (91.2 cm)

*32

¹⁄₂

(82.6 cm)

min.

*46

¹⁄₂

"

 

(118.0 cm)

max.

**32

¹⁄₂

"

 

(82.6 cm)

min.

**52

⁹⁄₁₆

(133.5 cm)

max.

27" (68.6 cm)

Summary of Contents for JXI8536DS0

Page 1: ...nnair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou...

Page 2: ...OTTE 28 Nettoyage 28 SCH MA DE C BLAGE 29 ASSISTANCE OU SERVICE 30 Au Canada 30 Accessoires 30 GARANTIE 31 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be...

Page 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...

Page 4: ...ial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows doors and...

Page 5: ...to seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold Weather Installations An additional back draft damper should be installed to minimize backward cold air...

Page 6: ...k Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring fo...

Page 7: ...power supply cable and drill a 1 3 cm diameter hole for wire access 2 Run wire through the home power supply cable according to the National Electrical Code or CSA Standards and local codes and ordin...

Page 8: ...ulk to seal all openings Non Vented Recirculating Installation 1 Attach the air deflector to the upper horizontal support using 4 mounting screws 2 Measure the length of 6 15 2 cm duct needed to conne...

Page 9: ...port frame The larger hole in the flanges of the upper duct cover must be outside the smaller hole in the mating flange of the other upper duct cover 2 Secure the upper duct covers together with two 3...

Page 10: ...ced over the plastic clip to secure the lower duct covers together at the bottom 7 Secure the lower duct covers together at the top using plastic clips 2 Use one plastic clip on each side 8 Secure the...

Page 11: ...tween the gas cooktop and electric cooktop modes The Auto button light will flash 5 times when the range hood is changed to the electric cooktop mode Auto Sense is now set to work with electric cookto...

Page 12: ...ing Method Liquid detergent soap and water or all purpose cleanser Wipe with damp soft cloth or nonabrasive sponge and then rinse with clean water and wipe dry Metal Grease Filter 1 Open the stainless...

Page 13: ...fications Power Supply Frequency Power Absorbtion 120 VAC 60 HZ 420 W Motor Resistance Blue Black Blue Grey Blue Red Blue White 9 8 14 3 18 21 6 SE130B RD M 3 2 1 4 5 6 7 8 9 BU YL GN BR YL WH RD GY B...

Page 14: ...h any questions or concerns at Jenn Air Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Can...

Page 15: ...rs preservation solutions etc 5 Defects or damage caused by the use of non genuine Jenn Air parts or accessories 6 Conversion of products from natural gas or L P gas 7 Damage from accident misuse abus...

Page 16: ...W10674115D 2015 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 3 15 Printed in Mexico Imprim au Mexique...

Reviews: