PRODUCT DATA SHEETS

BASE GRILLE WATER FILTRATION SYSTEM

MODEL WF-L200V CAPACITY 200 GALLONS (757 LITERS)

MODEL WF-NL120V CAPACITY 120 GALLONS (454 LITERS)

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The 

concentration of the indicated substances in water entering the system was reduced to a concentration less than or 

equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.

Substance 

Reduction Aesthetic 

Effects

NSF Reduction 

Requirements

Average 

Influent

Influent 

Challenge 

Concentration

Maximum 

Effluent

Average 

Effluent

Minimum % 

Reduction

Average % 

Reduction

Chlorine Taste/Odor 

Particulate Class III*

≥50%  

≥85%

1.9 mg/L 

49,333/mL

2.0 mg/L ± 10% 

At least 10,000 

particles/mL

0.07 mg/L 

640 mg/L**

0.06 mg/L  

312 mg/L

>75.0%  

98.7%

>75.0%  

99%

Contaminant 

Reduction

NSF Reduction 

Requirements

Average 

Influent

Influent 

Challenge 

Concentration

Maximum 

Effluent

Average 

Effluent

Minimum % 

Reduction

Average % 

Reduction

Lead: @ pH 6.5  

Lead: @ pH 8.5

0.01mg/L 

0.01mg/L

0.14 mg/L*** 

0.15 mg/L***

0.15 mg/L ± 10% 

0.15 mg/L ± 10%

0.0014 mg/L 

0.0069 mg/L

0.0011 mg/L 

0.0042 mg/L

99.0%  

95.4%

99.21% 

97.08%

Mercury: @ pH 6.5 

Mercury: @ pH 8.5

0.002 mg/L 

0.002 mg/L

0.0059 mg/L 

0.0054 mg/L

0.006 mg/L ± 10% 

0.006 mg/L ± 10%

0.0009 mg/L 

0.0007 mg/L

0.0004 mg/L 

0.00043 mg/L

84.74%  

87.03%

92.47% 

91.93%

Benzene

0.0050 mg/L

0.0157 mg/L

0.015 ± 10%

0.002 mg/L

0.00083 mg/L 87.26%

94.71%

p-dichlorobenzene

0.075 mg/L

0.210 mg/L

0.225 ± 10%

0.0005 mg/L 0.0005 mg/L

99.76%

99.76%

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).  

Temp. = 63°F (17.2°C).

 

It is essential that operational, maintenance, and 

filterreplacement requirements be carried out for the 

product toperform as advertised.

 

Model WF-L200V: The filter monitor system 

measures theamount of water that passes 

through the filter and alerts youto replace the 

filter. When 90% of the filter’s rated life is used,the 

filter indicator light changes from green to yellow. 

When100% of the filter’s rated life is used, the filter 

indicator lightchanges from yellow to red, and it 

is recommended that youreplace the filter. Use 

replacement cartridge L200V / NL120V,part #4396702. 

2014 suggested retail price of $32.99 U.S.A./$49.99 

Canada. Prices are subject to change without notice.

Model WF-NL120V:

 Change the water filter cartridge 

every6-9 months. Use replacement cartridge L200V 

/ NL120V, part#4396702. 2014 suggested retail price 

of $32.99 U.S.A./$49.99 Canada. Prices are subject to 

change without notice.

 

The product is for cold water use only.

 

Do not use with water that is microbiologically unsafe 

or ofunknown quality without adequate disinfection 

before or afterthe system.

 

Refer to the front cover or “Accessories” section for 

theManufacturer’s name, address and telephone 

number.

 

Refer to the “Warranty” section for the Manufacturer’s 

limitedwarranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure 

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 37.8° C)

Service Flow Rate

0.5 GPM (1.89 L/min.) @ 60 psi. 

(413.7 kPa)

Tested and certified by NSF International against ANSI/NSF Standard 

42 for the reduction of Chlorine, Taste and Odor, Particulate Class lll*; 

and against ANSI/NSF Standard 53 for the reduction of Lead, 

Mercury, Benzene, and p-dichlorobenzene.

*Class III particle size: >5 to <15 um 

**Test requirement is at least 10,000 particles/mL of AC Fine Test Dust. 

***These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. 

®

NSF is a registered trademark of NSF International.

Summary of Contents for JUCFP242HM00

Page 1: ...parts accessories or service call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Pour des ques...

Page 2: ...nnes de courant 37 Entretien avant les vacances 37 D PANNAGE Utilisation 37 Temp rature et humidit 37 Tiroirs 38 ASSISTANCE Aux U 39 Au Canada 39 Accessoires 39 Fiches de donn es de produitS 40 Garant...

Page 3: ...e of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance To avoid the risk of children becoming trapped and suffocat...

Page 4: ...RATOR FREEZER DRAWERS WITH ICE MAKER AND WATER FILTER Upper refrigerator drawer and lower freezer drawer provide additional storage options in the kitchen or other areas of the home Factory installed...

Page 5: ...trength inextricable from beauty Forged in the fires of progress the RISE design expression towers over stagnant uninspired designs that have inherited undeserved standing 7 NOIR Design Expression Los...

Page 6: ...or drawers to be flush with the front of the base cabinets remove any baseboards or moldings from the rear of the opening See Product Dimensions and later in this section Opening Dimensions It is reco...

Page 7: ...1 25 mm below the refrigerator drawers add 3 4 19 mm to the height dimensions The power cord is 60 1 52 m long RISE NOIR OVERLAY FRONT VIEW DRAWER WIDTH DIMENSIONS RISETM NOIRTM TOP VIEW OVERLAY TOP...

Page 8: ...ning For the installation of the customer panel you will need the following parts 16 screws SS Flat M4x12 tapping 1 4 Self tap wood screws 4 Drawer overlay hook plate right SPHC T 2 3 4 Drawer overlay...

Page 9: ...e valve complies with your local plumbing codes Do not use a piercing type or 3 16 4 76 mm saddle valve which reduces water flow and clogs more easily WATER PRESSURE A cold water supply with water pre...

Page 10: ...clamp screws slowly and evenly so washer makes a watertight seal Do not overtighten or you may crush the copper tubing 7 Slip the compression sleeve and compression nut on the copper tubing as shown I...

Page 11: ...precise as possible If the custom panel is incorrectly placed the panel may interfere with optimal use of the drawers 1 Attach the custom handle of your preference on the overlay before attaching the...

Page 12: ...minimum turn all four leveling bolts equally to the left to raise the leveling legs this will lower the appliance Recheck the level 4 Open both drawers less than midway Place the level on the side fla...

Page 13: ...be correct for normal household usage The refrigerator control is set correctly when milk or juice is as cold as you like The freezer control is set correctly when ice cream is firm The actual tempera...

Page 14: ...ned water supply Water softener chemicals such as salt can damage parts of the ice maker and lead to poor quality ice If a softened water supply cannot be avoided make sure the water softener is opera...

Page 15: ...replacing the water filter reset the water filter indicator Press and hold RESET FILTER for 3 seconds The indicator light will turn Off NOTE These features will not appear on your control unless you...

Page 16: ...less Steel Cleaner and Polish to come into contact with any plastic parts such as the trim pieces or drawer gaskets If unintended contact does occur clean plastic part with a sponge and mild detergent...

Page 17: ...ssible Are the controls not set correctly for the surrounding conditions Refer Controls section Are the drawers not closed completely Close the drawers firmly If they do not close completely see The d...

Page 18: ...is humid Is the food packaged correctly Check that all food is securely wrapped Dry damp food containers before placing in the refrigerator drawers Are the controls set correctly for the surrounding c...

Page 19: ...the JennAir designated service company in your area you can also look in your telephone directory Yellow Pages FOR FURTHER ASSISTANCE If you need further assistance you can write to JennAir with any...

Page 20: ...equirements be carried out for the product toperform as advertised Model WF L200V The filter monitor system measures theamount of water that passes through the filter and alerts youto replace the filt...

Page 21: ...om the date of purchase when this major appliance is installed operated and maintained according to instructions attached to or furnished with the product JennAir brand will pay for factory specified...

Page 22: ...or service or repair of this major appliance other than the representations contained in this warranty If you want a longer or more comprehensive warranty than the limited warranty that comes with thi...

Page 23: ...2019 All rights reserved Used under license in Canada Tous droits r serv s Utilis sous licence au Canada 05 19 W11357308B...

Reviews: