CUTOUT DIMENSIONS FOR OVENS INSTALLED UNDER COOKTOP

IMPORTANT: Observe all governing codes and ordinances. Cooktop must be approved for use over an oven. See Cooktop Installation 
Instructions for cutout dimensions. Center the cooktop cutout over oven cutout.

To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, 
delaminate or sustain other damage. This oven has been designed in accordance with UL and CSA International and complies with the 
maximum allowable wood cabinet temperatures of 194°F (90°C).

Approved Built-In Oven  and Electric Cooktop Combinations

For the approved model number combinations, refer to the undercounter label located on top of the oven chassis and on the 
bottom of the cooktop burner box.

NOTE: For undercounter installation, it is recommended that the junction boxes for the oven and cooktop be located in the adjacent 
right or left cabinet. A 1" (2.5 cm) minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall 
surface to pass the appliance cable through to the junction box.

A

E

F

G

H

B

C

C

D

A. 24" (61 cm) minimum cabinet depth
B. 25" (63.5 cm) countertop depth

C. Recommended oven and cooktop junction box locations
D. Allow 

⁵⁄₈

" (1.6 cm) for oven trim to overlap on each side.

E. 27¾" (70.5 cm) recommended cutout height (will fit cutout height 

from 27" [68.6 cm] to 29

¹⁄₁₆

" [73.8 cm])

F. 34½" (87.6 cm) minimum cabinet height from floor to bottom of 

countertop

G. 4

⁵⁄₈

" (11.7 cm) from floor

H. See Cutout Dimensions chart.

NOTE: 24" (61.0 cm) minimum cutout depth required.

CUTOUT DIMENSIONS

Oven Size

Oven Cutout Dimension

27" (68.6 cm)

30" (76.2 cm)

25

¹⁄₂

" (64.8 cm) recommended

28½" (72.4 cm) recommended (will fit cutout 
width from 28½" [72.4 cm] to 29" [73.7 cm])

W10176244B

Summary of Contents for JJW2330W

Page 1: ...ion Instructions packed with product Specifications subject to change without notice Ref W10221386C 07 30 09 27 68 6 CM AND 30 76 2 CM ELECTRIC SINGLE AND DOUBLE BUILT IN OVEN Product Dimensions Single Ovens Cabinet Dimensions Single Ovens Single Oven Undercounter without cooktop installed above 27 68 6 cm models A 25 64 1 cm max recessed width B 29 75 0 cm max overall height C 26 67 9 cm max over...

Page 2: ...utout height from 49 126 4 cm to 131 9 cm G 24 61 0 cm minimum cutout depth A B C D E F G Single Ovens Installed in Cabinet 27 68 6 cm models A 27 68 6 cm min cabinet width B 29 75 5 cm from bottom of cutout to bottom of upper cabinet door C 32 81 3 cm recommended bottom of cutout to floor 4 10 2 cm to 32 81 3 cm bottom of cutout to floor is acceptable D 25 64 8 cm cutout width E 1 3 8 cm min bott...

Page 3: ...burner box NOTE For undercounter installation it is recommended that the junction boxes for the oven and cooktop be located in the adjacent right or left cabinet A 1 2 5 cm minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface to pass the appliance cable through to the junction box A E F G H B C C D A 24 61 cm minimum cabinet depth B 25 63 5...

Page 4: ...stallation be located in the adjacent right or left cabinet A 1 2 5 cm minimum diameter hole should have been drilled in the lower right or left corner of the side wall surface to pass the gas supply line A C D F G H J K M L D B E E I I A 24 61 cm minimum cabinet depth B 1 2 5 cm clearance from the top of junction box to the bottom of the countertop C 25 63 5 cm countertop depth D Recommended grou...

Page 5: ...la table de cuisson REMARQUE Pour l installation sous un plan de travail on recommande que les boîtiers de connexion pour four et table de cuisson soient situés dans le placard adjacent à droite ou à gauche Un trou de diamètre 1 2 5 cm ou plus doit avoir été percé dans la partie supérieure de l angle arrière supérieur gauche ou droit de la surface de la paroi latérale pour le passage du câble d al...

Page 6: ...u de diamètre 1 2 5 cm ou plus doit avoir été percé dans l angle inférieur gauche ou droit de la surface de la paroi latérale pour le passage de la canalisation de gaz A C D F G H J K M L D B E E I I A Profondeur de placard 24 61 cm minimum B Dégagement de 1 2 5 cm du haut du boîtier de connexion au bas du plan de travaill C Profondeur du plan de travail 25 63 5 cm D Emplacement recommandé de la p...

Reviews: