Converting from Natural Gas to LP Gas
Converting the Burner Orifice Spuds
1. Remove the grates and burner caps.
2. Remove venture tube or burner base by removing 2
screws.
3. Trim a small piece of masking tape to the size of a
dime and place it over the end of a 5/16" or a 9/32"
(7mm) nut driver.
4. Firmly press the nut driver over the orifice spud and
loosen spud by turning counterclockwise. Carefully lift
the nut driver out of the burner throat. Orifice spud
should be captured in the recess. Repeat this step
for each burner.
5. Locate the LP orifice spud packet taped to the
underside of the burner box. The spuds have small
numbers stamped on the side. This number codes
the orifice diameter and its correct burner location.
NOTE:
See chart and graphics below for location of
components.
6. With the masking tape still in place in the recess of
the nut driver, press an LP orifice spud into the
recess so that it is snugly captured.
7. Carefully install the orifice spud in the appropriate
burner throat by turning clockwise to tighten.
8. Tighten to a torque of orifice 15 to 20 inch-lbs.
9. Replace burner base. Tighten screws to 25-30 inch-
lbs.
10. Repeat steps 2 through 9 for each burner.
11. Replace burner caps and grates.
12. Save orifices removed from appliance for future use.
Model JGC8645BDS
Orifice Spuds
Natural Gas
(burner)
Orifice
color or #
LP
(burner)
Orifice #
6.5K (CF)
Silver
5K (CF)
# 70
15K (RF)
# 49
8.5K (RF)
# 65
6.5K (CR)
Silver
5K (CR)
# 70
9.1K (RR)
Green
5.5K (RR)
# 69
9.1K (LF)
Green
5.5K (LF)
# 65
10.5K (LR)
Yellow
8.5K (LR)
# 69
Model JGC8430BD*
Orifice Spuds
Natural Gas
(burner)
Orifice #
LP
(burner)
Orifice #
15K (RF)
# 190
14K (RF)
# 114
9.2K (RR)
# 145
9.1K (RR)
# 91
5K (LF)
# 107
4K (LF)
# 64
10.5K (LR)
# 155
9K (LR)
# 91
Converting Pressure Regulator for LP/Propane
1. Remove pressure regulator cap using a wrench.
2. Apply sideward finger pressure to remove pin from
cap.
Apply sideways
finger pressure
to remove pin
from cap
3. Apply downward finger pressure at the disc edges to
place pin into the cap.
LP
L.P.
Natural
NAT
4. Place pressure regulator cap on pressure regulator
and tighten.
Low Flame Adjustment
Properly adjusted burner flames are clean and blue with
a distinct inner cone approximately ½ inch long.
1. Light burner and set control knob for low flame.
2. Remove control knob from valve stem.
3. Insert a slender thin bladed screwdriver into the
recess at center of valve stem and engage blade with
slot in adjusting screw.
4. Turn adjusting screw clockwise until tight. Do not over
tighten.
•
Clockwise to decrease
•
Counterclockwise to increase
5. Repeat process for remaining burners.
After adjusting the screw, the burner should produce a
stable, steady blue flame of minimum size. The setting
should be checked by turning the knob from high to low
several times without extinguishing the flame.
This operation will automatically provide the proper flame
size at medium setting.
After conversion steps have been completed, check the
appearance of each burner flame at high and low
settings. If the flames appear too large or small, review
each step to verify it was completed correctly.
Summary of Contents for JGC8430BDB/Q/S/W
Page 21: ... 2004 Maytag Services 16023565 A 1 Appendix A ...
Page 25: ... 2004 Maytag Services 16023565 A 5 Installation Instructions Ducting Instructions JGD8348CDP ...
Page 26: ...A 6 16023565 2004 Maytag Services Installation Instructions Ducting Instructions JGD8348CDP ...
Page 27: ... 2004 Maytag Services 16023565 A 7 Installation Instructions Ducting Instructions JGD8348CDP ...
Page 28: ...A 8 16023565 2004 Maytag Services Installation Instructions Ducting Instructions JGD8348CDP ...
Page 31: ... 2004 Maytag Services 16023565 B 1 Appendix B ...
Page 41: ... 2004 Maytag Services 16023565 C 1 Appendix C ...