3
Location Requirements
To ensure proper ventilation for your refrigerator, allow for a
¹⁄₂
"
(1.25 cm) space at the top and behind the refrigerator. If your
refrigerator has an ice maker, allow extra space at the back for the
water line connections. When installing your refrigerator next to a
fixed wall, leave 2
¹⁄₂
" (6.3 cm) minimum on the hinge side (some
models require more) to allow for the door to swing open.
NOTE: It is recommended that you do not install the refrigerator
near an oven, radiator, or other heat source. Do not install the
refrigerator in a location where the temperature will fall below 55°F
(13°C).
Electrical Requirements
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.
Recommended Grounding Method
A 115 Volt, 60 Hz., AC only 15- or 20-amp fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, turn Cooling OFF, and then disconnect the
refrigerator from the electrical source. When you are finished,
reconnect the refrigerator to the electrical source and turn Cooling
ON. See “Using the Controls.”
Water Supply Requirements
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
TOOLS NEEDED:
IMPORTANT:
■
All installations must meet local plumbing code requirements.
■
Do not use a piercing-type or
³⁄₁₆
" (4.76 mm) saddle valve
which reduces water flow and clogs more easily.
■
Use copper tubing and check for leaks. Install copper tubing
only in areas where the household temperatures will remain
above freezing.
■
For models with water filters, the disposable water filter
should be replaced at least every 6 months.
Water Pressure
A cold water supply with water pressure of between 35 and
120 psi (241 and 827 kPa) is required to operate the water
dispenser and ice maker. If you have questions about your water
pressure, call a licensed, qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of the
refrigerator needs to be between 35 and 120 psi (241 and
827 kPa).
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from refrigerator.
Failure to do so can result in death, explosion, or fire.
2
¹⁄₂
" (6.3 cm)
¹⁄₂
" (1.25 cm)
■
Flat-blade screwdriver
■
⁷⁄₁₆
" and
¹⁄₂
" Open-end or two
adjustable wrenches
■
¹⁄₄
" Nut driver
■
¹⁄₄
" Drill bit
■
Cordless drill
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING