Oven Control Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
16025924 4
February
2005
©2005 Maytag Services
Control Component
Test
Procedure
Results
EOC II
End-of-Timer
Reminder beeps
Press
Setup Options
and the applicable timer
pad (
Timer 1
or
Timer 2
) simultaneously.
Selects the number of beeps emitted
when a timed bake cycle ends.
EOC II
Control Lock
Press
Setup Options
and the
Control Lock
pad
(also the
1
pad) simultaneously.
Press
Autoset
to select option (enable
or disable). The timer, clock and oven
light are operational.
EOC II
Twelve Hour off/
Sabbath mode
Press
Setup Options
and the
12 Hour Off
pad
(also the
2
pad) simultaneously.
Disables the normal 12-hour shutoff,
allowing the oven to operate indefinitely.
EOC II
Sound Level
(Beeper Volume)
Press
Setup Options
and the
Sound Level
pad
(also the
3
pad) simultaneously.
Press
Autoset
to select setting (I lowest
through IIIIIIII 8 highest).
EOC II
24-Hour Clock
Press
Setup Options
and the
12/24 Hour Clock
pad (also the
4
pad) simultaneously.
Press
Autoset
to select option (12-hour
time or 24-hour time).
EOC II
Scroll Speed
Press
Setup Options
and the
Scroll Speed
pad
(also the
5
pad) simultaneously.
Press
Autoset
to set speed of displayed
messages (slow, medium, fast).
EOC II
End-of-Cook-Time
Signal
Press
Setup Options
and
Cook Time Beeps
pads (also the
6
pad) simultaneously.
Press
Autoset
to set the number of
beeps emitted at the end of a
"
clock-
controlled
"
cook cycle.
EOC II
Temperature Display
Press
Setup Options
and the
Temp C/F
pad
(also the
7
pad) simultaneously.
Press
Autoset
to select option
(°F or °C).
EOC II
Language Display
Press
Setup Options
and the
Language
pad
(also the
8
pad) simultaneously.
Press
Autoset
to select option
(English, French or Spanish).
EOC II
Factory Default
Press
Setup Options
and the
Default
pad (also
the
9
pad) simultaneously.
Press
Autoset
to reset clock to factory
settings.
EOC II
Clock Display
Press
Setup Options
and the
Display On/Off
pad
(also the
Clock
pad) simultaneously.
Press
Autoset
to select clock display
(on or off).
EOC II
Test Access
Press and hold
Cancel
and
Broil
pads for 3
seconds at power up or within 5 minutes of power
up mode. See "Quick Test Mode."
Allows access to each function for
testing purposes.
Control Panel Assembly
Closed circuitry resistance
(defined as continuity):
1350 – 2250
Ω
for Cancel pads 1 & 20
1275 – 2125
Ω
for Cancel pads 2 & 19
320 – 2200
Ω
for all other pads
Open circuitry resistance:
Greater than 10 M
Ω
Pin 20
Pin 1
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Clock
Quick Preheat
Bake
Broil
Keep Warm
Convect Warm
Convect Roast
Cook Time
Stop Time
Clean
Proofing
Drying
Meat Probe
Vent Fan
Auto Set
Timer 1
Timer 2
Oven Light
Trace
7 & 8
14 & 15
10 & 14
6 & 7
6 & 8
5 & 6
4 & 5
4 & 6
3 & 4
3 & 6
1 & 2
or
1 & 19
or
2 & 20
or
19 & 20
13 & 14
16 & 18
15 & 16
16 & 17
12 & 13
6 & 10
3 & 18
10 & 18
14 & 18
15 & 18
8 & 10
9 & 10
6 & 18
11 & 12
17 & 18
12 & 14
10 & 12
10 & 11
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity