-15-
PROPANE GAS (LP) TO NATURAL GAS CONVERSION INSTRUCTIONS
WARNING
TO CONVERT APPLIANCE FOR USE WITH
NATURAL GAS
1.
Replace all orifice hoods . . . Perform step 1
through 4 on pages 12 & 13.
Locate the (4) four
Natural Gas hoods (with small numbers stamped on
their sides) saved from original Natural Gas model. The
two hoods with .0520 (#55 orifice) stamped on them
are for the left front and left rear burners. The two
hoods with the .0595 (#53 orifice) stamped on them are
for the two right burners.
To make these conversion adjustments follow the
instructions and illustrations (“A” through “D”) on
pages 13 and 14.
2.
Invert cap in pressure regulator (see illustration
“A”).
With the appliance installed, the regulator is
located on the center underside of the appliance at the
inlet to the gas manifold. Identify the type of regulator
on the unit and follow the instructions in the appropriate
illustration.
3.
Adjust low flame setting for each burner.
Follow the
instructions for burner low flame adjustment on page
14 to increase the simmer flame size.
Natural Gas input required - 36,000 BTU/hr.
Natural Gas conversion is to be performed by a
JENN-AIR AUTHORIZED SERVICE CONTRACTOR (or
other
qualified
agency)
in
accordance
with
the
manufacturer’s
instructions
and
all
codes
and
requirements of the authority having jurisdiction. Failure
to follow instructions could result in serious injury or
property damage. The qualified agency performing this
work assumes responsibility for this conversion.
Natural gas supply line must have a natural gas service
regulator. Inlet pressure to this appliance should be
reduced to a maximum of 14 inches water column (0.5
pounds per square inch (P.S.I.) liquified petroleum
(L.P.)/propane gas supply line must have a L.P. gas
pressure regulator. Inlet pressure to this appliance should
be reduced to a maximum of 14 inches water column (0.5
P.S.I.). Inlet pressures in excess of 0.5 P.S.I. can damage
the
appliance
pressure
regulator
and
other
gas
components in this appliance and can result in a gas leak.
WARNING
ELECTRICAL POWER AND GAS MUST BE
TURNED OFF PRIOR TO CONVERSION.
Manifold - Natural Gas pressure required - 5
²
Water
Column.
Incoming Natural Gas pressure required to regulator - 6
²
-
7
²
Water Column.
INCHES
BURNER
BTU/hr
DIAMETER
COLOR
Left Rear (LR)
8,000
.0520
Brass
Left Front (LF)
8,000
.0520
Brass
Right Rear (RR)
10,000
.0595
Brass
Right Front (RF)
10,000
.0595
Brass