background image

Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing  
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.

JENN-AIR

®

 DETAILED PLANNING DIMENSIONS

3 of 3

JRC120112  07/2012  

OPENING/CLEARANCE DIMENSIONS

BACK VIEW

DIShwAShERS

JDB8700AW, JDB8200AW, JDB8000AW – 23

3

/

4

" x 33

7

/

8

" x 26

7

/

8

"

FRONT VIEW

F

Floor

Wall

D*

A

H

B

C

B

I

F G

E

F

Floor

Wall

D*

A

H

B

C

B

I

F G

E

sIDE VIEW

MODEL #

JDB8700AW 
JDB8200AW 
JDB8000AW

in

cm

A

Width (min.)

24

61.0

B

Width of possible utility installation area  
(back wall)

6

3

4

17.2

C

Width of clear area (back wall)

10

1

2

26.7

 D*

Height with wheels removed (min.)

33

7

8

86.0

E

Height of possible utility installation area  
(back wall)

2

1

2

6.4

F

Height of possible utility installation area  
(back/side wall)

6

1

4

15.9

G

Height of clear area (side wall)

3

7.6

H

Depth (min.)

24

61.0

I

Depth of utility location (side wall)

4

10.2

Electrical, water and drain connections  
may be installed in shaded areas

Recommended drain connection location –  
closest to sink

1

1

2

 dia.

3.8 dia.

Recommended electrical connection location –  
right-hand side or back wall

1

1

2

 dia.

3.8 dia.

Recommended water connection location –  
left-hand side or back wall

1

2

 dia.

1.3 dia.

  * Measured from the lowest point on the underside of countertop. 

ELECTRICAL REQuIREMENTs

120 volt, 60 Hz, AC only, 15- or 20-amp fused, grounded circuit is required.  
A dedicated circuit is recommended. Use an outlet that cannot be turned off  
by a switch. Do not use an extension cord.

WATER suppLY REQuIREMENTs

120°F (49°C) hot water supply with water pressure between 20 and  
120 psi (138 and 862 kPa) is required. If you have questions about your  
water pressure, call a licensed, qualified plumber. 

DRAIN REQuIREMENTs

Connect drain hose to waste tee or disposer inlet above drain trap.  
Maximum drain hose length 12' (3.7 m). 

LOCATION REQuIREMENTs

Corner locations require a 2" (5.1 cm) minimum clearance between  
the side of the dishwasher door and the wall or cabinet. 

F

Floor

Wall

D*

A

H

B

C

B

I

F G

E