CAUTION
Burner adjustments should only be performed after
the burners have cooled.
Always tighten the locking nut before relighting the
burner
Locking Nut
GAS FLOW ADJUSTMENTS
•
If the flames have yellow tips, loosen the locking
nut and move the bolt in a clockwise direction.
•
If the flames are making excessive noise or
lifting, loosen the locking nut and turn the bolt in
a counter-clockwise direction.
•
For questions regarding flame stability, contact
customer service at 1-800-554-5799.
Adjustment Bolt
INSTALLER FINAL CHECK
Specified clearance maintained 24 in. from
combustible materials.
All internal packaging has been removed.
All the burners are factory installed.
Model 720-0139-NG
The hose and regulator are properly
connected.
The unit has been tested and is free of
leaks.
The gas supply shut off valve has been
located.
WARNING
1. The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressure in excess of ½
psi (3.5 kpa).
2. The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing
its individual manual shutoff valve during any pressure testing of the gas supply piping system at
test pressures equal to or less ½ psi (3.5 kpa).
Model 720-0142-LP
WARNING
1. Do not store spare LP gas cylinders under or near this appliance.
2. Never fill the cylinder beyond 80 percent capacity.
3. If the information above is not followed exactly, a fire resulting in death or serious injury could occur.