DSC-Q01

Summary of Contents for DSC-Q01

Page 1: ...DSC Q01 1axis display user s manual DONG SAHN JENIX CO LTD...

Page 2: ...eration 1 Input preset 2 Display zero 3 ABS INC conversion 4 ABS number designation Function 1 Changing resolution 1 5 1000 2 1 1000 3 1 100 4 5 10000 2 Changing process direction 3 Rate or correction...

Page 3: ...6 Initializing 1 ABS initializing 2 Program initializing 7 Test Caution and trouble shooting 1 Caution 2 Trouble shooting 3 Pin information 3 5 3 6 3 6 4 1 4 2 4 3...

Page 4: ...escription of DSC Q01 counter...

Page 5: ...a 2 Axis selection key 3 Axis Zero key 4 Power key 5 Number key 6 Function key shows position value select present axis make the display value zero turn on off the power 0 9 numbers calls one of the f...

Page 6: ...2 Rear side 1 Power input 2 Connector DC adapter input to connect with a scale Keys Description...

Page 7: ...3 Connection Power socket a linear scale...

Page 8: ...Direction key Enter key On Off key Keys Description select axis make the axis zero input values decimal point value conversion to call function menu cancel present processing or operation absolute fun...

Page 9: ...Basic operation...

Page 10: ...designation key 99 ABS numbers can be saved 1 99 Move in the numbers by using arrow keys conversion from INC normal to ABS conversion from ABS to INC normal ABS 1 is flickering and disappeared This me...

Page 11: ...rs move by arrow keys To find ABS number 5 push arrow key until 5 shows To find ABS number 1 Ex push reverse arrow key until 1 shows To input coordinates of the axis to an ABS number type its value or...

Page 12: ...Function...

Page 13: ...call function menu 1 Changing resolution factory setting 5 1000 2 Direction change 3 Rate or correction 4 Double counting 5 Inch mm conversion 6 Initialization 7 Test function Function...

Page 14: ...1000 This resolution should be same as the scale s 5 1000 is basic factory setting After setting 0 000 will be shown 2 1 1000 This resolution should be same as the scale s 5 1000 is basic factory sett...

Page 15: ...on should be same as the scale s 5 1000 is basic factory setting After setting 0 000 will be shown 4 5 10000 This resolution should be same as the scale s 5 1000 is basic factory setting After setting...

Page 16: ...distance and displayed distance When there is a difference between If you input 0 000000 there will be nothing displayed Basic rate is 1 000000 input 1 0 1 0 or 1 000000 flickering instead this rate R...

Page 17: ...Ex Real distance is 100mm but the readout a display shows 100 4mm flickering 0 996 type 4 Double counting menu dIA diameter radius dIA is double of the radius...

Page 18: ...5 Inch mm conversion menu Inch 6 Initialization Reset menu rESEt 1 ABS initialization Please note that all of the preset ABS data will be removed...

Page 19: ...ncluding ABS will be removed All setting value returns to factory setting Factory setting resolution 5 1000 counting direction rate 1 000000 unit mm radius 7 Test function menu tESt Check if the LEDs...

Page 20: ...Caution and trouble shooting...

Page 21: ...r noise please leave any electronic appliances away from the display counter Please put any motor around the display counter Please leave the display counter away from high voltage or where the temper...

Page 22: ...cause inaccuracy needs cleaning Backlash of the machine tools can be another reason00 Readhead inside glass broken or connection failure can cause the problem Needs to be replaced If there is same am...

Page 23: ...DC adapter spec Input Output Size AC 100 240V 60Hz 0 6A DC5V 1A Internal diameter 2 1mm External diameter 5 5mm 3 PIN 6 pin Information...

Page 24: ...DSC Q01...

Page 25: ......