11
Step 12
:
Connect the electrical system.
Attention: electrical connection must be done by a licensed electrician.
Connect the wiring as per the wiring diagram and do pay careful attention to the number tubes attached on each threads of wire.
Wires of with the same number shall be connected together.
Step 13: Leveling
No vehicle on platforms when leveling.
Switch on and press the UP button when the green power indicating light is on. When the steel cable has been tightened,
measure if the two platforms are of the same height from the ground. If not, adjust the tightening screw fixed on top of the main
post.
Step14: Fix the expansion plug.
3.4. Items to be checked after installation.
S/N
Check items
YES NO
1
Are the posts vertical to the floor?
2
Is the oil hose well connected?
3
Is the steel cable well connected?
4
Are two platforms well connected?
5
Are electrical connections right?
6
Are the rest joints firmly screwed?
7
Are all items need lubricating added with grease?
4. Operation instructions
4.1 Precautions
4.1.1 Check all the joints of oil hose. Only when there is no leakage, the lift can start work.
4.1.2 The lift, if its safety device malfunctions, shall not be used.
Summary of Contents for JA4000F
Page 19: ...19 Annex2 Overall diagram ...
Page 20: ...20 Annex3 Floor plan Annex 4 Steel cable connection ...
Page 22: ...22 Annex 6 Wiring diagram Single phase ...
Page 23: ...23 Three phase ...
Page 24: ...24 ...
Page 25: ...25 ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 28: ...28 ...
Page 29: ...29 Annex7 Separate diagrams for the lift JA4000F ...
Page 37: ...37 Annex9 Size and weight requirements on vehicles ...
Page 38: ...38 Single fase 220V Electric diagram ...
Page 39: ...39 Three fase 380V Electric diagram ...
Page 40: ...40 ...
Page 41: ...41 ...