14
AF-1 and AF-2 fans user manual
The DMX address on AF-1 and AF-2 fans can be set to any channel from
1 to 512 using DIP-switch pins 1 - 10:
1. Decide on an available DMX address for each machine.
2. Look up the DIP-switch settings using the Martin Address Calculator at
http://www.martin.dk/service/utilities/AddrCalc/index.asp, or look for
the address in the DIP-switch settings table on page 15. For example,
to set the DMX address to 101, you need to set DIP-switch pins 1, 3, 6
and 7 to ON, as shown in the illustration below:
3. Power the controller and all devices off.
4. For each device, set the DMX address by setting DIP-switch pins 1
through 10 to the ON (1) or OFF (0) position as listed in the table on
the next page. As an example, channel 101 is highlighted in the table.