7. Stopping the Generator

1.

 Before stopping the generator, allow it to run for approximately 3 minutes with no consumers so that it can "cool    

    down".

2.

 Turn off the circuit breaker.

3.

 Turn the key/ignition switch to the "OFF" position.

4

. Turn the fuel cock lever to the "CLOSED" position.

8. Transportation and Storage

• When transporting the generator, ensure the starting switch is set to the "OFF" position and that the fuel valve is  
    set to the "Closed" position.  

• Keep the generator level to prevent fuel spillage. Fuel vapour or spilled fuel may ignite. Touching a hot engine can   
   cause serious burns or fires. 

• Let the engine cool before transporting or storing the generator.

• Make sure not to drop or strike the generator when transporting. Do not place heavy objects on top of the 
   generator during transit, storage or operation.

6. Connecting Consumers to the Generator

1. 

Connect the machine you want to use to the AC socket. 

Note: 

Do not exceed the specified load limit of the  

    specified maximum AC output.

2. 

Do not connect the generator to the household network as this may result in damage to the generator itself or to  

    other electrical appliances in your home

9. Operation Environment

• This unit can generate rated output under the following conditions:

• The Generator should work in low output under the following conditions:

Altitude

Ambient Temperature

Relative Humidty

0m

+20º

60%

Altitude

Ambient Temperature

Relative Humidty

>1000m

>40

º

90%

Summary of Contents for OLYMPUS

Page 1: ...OLYMPUS OLYMPUS User Manual v 1 2 2 8kVA Recoil Start With Electronic Ignition AVR JEFGENPET22...

Page 2: ...Consumers to the Generator 7 Stopping the Generator 8 Transportation and Storage 9 Operation Environment 10 Maintenance 11 Troubleshooting 12 Parts List Diagram 13 Circuit Diagram Limited Warranty Sta...

Page 3: ...t electric shock or fire never use the machine in rain or snow or connect the generator to a live circuit 12 Do not connect the generator to another power supply outlet 13 Protection against electrica...

Page 4: ...unit or refuelling an empty tank You can drain away air by loosening the connection between the injection pump and pipeline then drain the air until the fuel comes out Do not loosen or adjust either...

Page 5: ...rious burns or fires Let the engine cool before transporting or storing the generator Make sure not to drop or strike the generator when transporting Do not place heavy objects on top of the generator...

Page 6: ...help and advice and a full list of replacement parts Check Frequency Notes Checking and the engine oil With generator on level ground remove the oil filler cap and dipstick clean with a clean cloth In...

Page 7: ...d Replace the AVR 11 Technical Specification Noise Level Information The figures quoted in this table are emission sound power levels and are not necessarily safe working levels Whilst there is a corr...

Page 8: ...400500082 Frame 1 25 029021600037 Control panel 1 26 517050401204 Screw ST4 2X12 4 27 029940110001 Muffler protect side guard 1 28 029940101601 Muffler protect outside guard 1 12 Parts List and Parts...

Page 9: ...9 USER MANUAL 2 8kVA Petrol Generator JEFGENPET22 www jeffersontools com...

Page 10: ...kVA Petrol Generator JEFGENPET22 www jeffersontools com 13 Circuit Diagram Ground DC reset 9A 12V out POWER lamp purple purple AC 12V generator AC 230V blue AC breaker 230V 12A 1 ph socket 110V 16A 1...

Page 11: ...e repair or replacement of warranty covered equipment will be subject to a minimum of 90 days cover or the remaining duration of the warranty period from the original date of purchase Warranty Registr...

Page 12: ...e form online and submit it to us directly or download the form to print out and return by post Telephone Method Contact your Jefferson dealer or sales representative with the following information Mo...

Page 13: ...Where parts are not immediately available Jefferson will contact you with a revised date for completion of the repair General Warranty Enquiries For any further information relating to Jefferson warr...

Page 14: ...JEFGENPET22EL 2 8kVA 2 2kW Petrol Generator The conformity assessment procedure followed was in accordance with Annex VI of the Outdoor Noise Directive Notified Body SNCH Luxembourg GmbH No 0499 Measu...

Page 15: ...15 USER MANUAL 2 8kVA Petrol Generator JEFGENPET22 www jeffersontools com 14 Notes...

Page 16: ...k Chester United Kingdom CH4 9QR Tel 44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating...

Reviews: