background image

18

USER MANUAL v1.1

JEFGENPET35EL

4.4kVA Petrol Generator - Key Start 

www.jeffersontools.com

  EC DECLARATION OF CONORMITY

 

We, Jefferson Professional Tools & Equipment, as the authorised European  

Community representative of the manufacturer, declare that the following equipment  

conforms to the requirements of the following: 

Directive / Standard / Regulation

Description:

2000/14/EC (as amended)

Noise Emission in the Environment by Equipment for Use Outdoors

2014/30/EU (as amended) 

Electromagnetic Compatibility

2006/42/EC (as amended)

Machinery Directive 

(EU) 2016/1628 (as amended)

Non Road Mobile Machinery Directive

Equipment Category: 

Power Generator (Item 45)

Product Name/Model: 

JEFGENPET35EL

 - 4.4kVA / 3.5kW Petrol Generator (Key Start)   

Measured Sound Power Level:

 

 

Guaranteed Sound Power Level:

 

97dB

97dB

The conformity assessment procedure followed was in accordance 
with Annex VI of the Outdoor Noise Directive

EU type-approval number: 

e13*2016/1628*2016/1628SRA1/P*0027*01

Signed by: 

 

Stephen McIntyre  

Position in the company:  

Operations Director

Date:  

05 October 2020 

Technical file holder's address as shown below

Name and address of manufacturer
or authorised representative: 

Jefferson Tools, Herons Way, Chester Business Park, 
Chester, United Kingdom, CH4 9QR

Telephone:

 +44 (0)1244 646 048  

Fax: 

+44 (0)1244 241 191

 

Email: 

[email protected]

Summary of Contents for OLYMPUS JEFGENPET35EL

Page 1: ...OLYMPUS OLYMPUS User Manual v 1 1 JEFGENPET35EL PETROL GENERATOR Key Start With Electronic Ignition AVR 7 5HP OHV Petrol Engine Stage V...

Page 2: ......

Page 3: ...designed and contains all the necessary information to ensure its correct and safe use We recommend that you read the information supplied before carrying out any maintenance or repair By following al...

Page 4: ...s Whilst there is a correlation between the emission and exposure levels this can not be used reliably to determine whether or not further precautions are required Factors that influence the actual le...

Page 5: ...plications on employers to ensure the safety of electrical devices in the workplace The regulations dictate that all portable equipment must be inspected regularly and tested to ensure that it is safe...

Page 6: ...on circuit breakers specifically matched to the generating set If the circuit breakers require replacement they must be replaced with a circuit breaker having identical ratings and performance charac...

Page 7: ...minutes 2 Open the Fuel Cock 3 Put the starting switch into the RUN position 4 Hold the starting recoil handle loosely and pull the cord out it until you feel resistance then return it slowly CONNECTI...

Page 8: ...hat the fuel valve is set to the CLOSED position Keep the generator level to prevent fuel spillage Fuel vapour or spilled fuel may ignite Touching a hot engine can cause serious burns or fires Let the...

Page 9: ...very three years Check the battery and electrolyte levels Before use Notes Checking and the engine oil With generator on level ground remove the oil filler cap and dipstick clean with a clean cloth In...

Page 10: ...he upper and lower level markers Not enough speed or force used on the starter recoil handle See section 5 Starting the Generator The fuel nozzle is blocked or dirty Clean tthe fuel nozzle Generator f...

Page 11: ...11 USER MANUAL v1 1 JEFGENPET35EL 4 4kVA Petrol Generator Key Start www jeffersontools com CIRCUIT WIRING DIAGRAM...

Page 12: ...12 USER MANUAL v1 1 JEFGENPET35EL 4 4kVA Petrol Generator Key Start www jeffersontools com PARTS DIAGRAM GENERATOR...

Page 13: ...r 5 5 13 Mufler gasket 1 46 Flange bolt M5x16 7 14 Fuel tank 1 47 Full thread bolt M5x20 3 15 Shock absorption 4 48 Nut M5 6 16 7 Clamp 1 49 Flat washer M5 8 17 4 5mm Fuel pipe 0 2 50 Flange bolt M5x1...

Page 14: ...14 USER MANUAL v1 1 JEFGENPET35EL 4 4kVA Petrol Generator Key Start www jeffersontools com PARTS DIAGRAM ENGINE...

Page 15: ...Rod Assy 1 57 Carburator Gasket 1 17 Piston Pin 1 58 Bolt M5x30 1 18 Piston 1 59 Air Cleaner Gasket 1 19 Piston Ring Set 1 60 Air Cleaner 1 20 Low Oil Sensor 1 61 Shroad Comp 1 21 Bolt M6x22 3 62 Shee...

Page 16: ...recommended as it eliminates the need to provide proof of purchase should a warranty claim be necessary Warranty Repair Should Jefferson confirm the existence of any defect covered by this warranty t...

Page 17: ...need of repair and any repairs needed are covered by the warranty policy In order to qualify for warranty cover all equipment presented must have been used serviced and maintained as instructed in th...

Page 18: ...ded Non Road Mobile Machinery Directive Equipment Category Power Generator Item 45 Product Name Model JEFGENPET35EL 4 4kVA 3 5kW Petrol Generator Key Start Measured Sound Power Level Guaranteed Sound...

Page 19: ......

Page 20: ...44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating instructions outlined in this manual...

Reviews: