4. Operation

• 

Use clamps or other practical ways to secure and support the workpiece to a stable platform. Holding the work by hand is unstable and may 
lead to loss of control. Only work on a workpiece that is properly secured.

• 

Do not force or modify the tool. Use the correct tool for your application. 

• 

Check for misalignment or binding of moving parts, breakages of parts, damaged air hose (not included), and any other condition that may 
affect the tool's operation. If damage is detected ensure that you have the tool repaired before use. 

• 

Ensure you read, understand and apply safety instructions before use.

• 

Only use impact sockets which are specifically designed for use with an impact wrench (contact your nearest Jefferson dealer for advice on 
the best sockets to use.

• 

Place the socket fully over the working nut and depress the trigger to operate the wrench.

• 

Do not use any additional force upon the wrench in order to remove a nut.

• 

Do not allow the wrench to free-run for an extended period of time as this will reduce bearing life.

• 

To operate, check connections are correct and safe, pull the trigger on the handle. 

• 

To operate with a forward rotation move the lever on the rear of the wrench to the "F" position. 

• 

To operate with a reverse motion move the lever to the "R" position. 

• 

This equipment is designed as a “plug-and-run” type device. 

• 

The tool will stop operation/rotation in a few seconds after relieving the trigger control.

5. Maintenance

Lubrication 

Before connecting the air hose, apply 4 to 5 drops of air line oil, or equivalent, at the air inlet. Repeat this process after every 3 to 4 hours of use 
and as necessary. Do not lubricate tools with flammable or volatile liquids such as petrol, diesel or jet fuel.

Fittings 

Check fittings and accessories daily and ensure all parts are fastened securely and in good working condition .

Cleaning  

Ensure handle is kept clean and free from oil, dust and dirt to ensure that the equipment can be gripped securely. 
Ensure that the handle is cleaned before and during use using a clean, dry cloth.

Storage 

Ensure that the tool is stored in clean, dry environment. If the tool is not in use for a period of time, any residual moisture inside of the wrench 
could result in rusting. Before storing after use, the wrench should be oiled at the air inlet with air line oil and allowed to operate for a short period 
before storing. 

Repairs 

Ensure that all repairs are carried out by Jefferson authorised engineers or at your nearest authorised Jefferson Repair Centre.

Summary of Contents for JEFIW772

Page 1: ...User Manual v 1 1 JEFIW772 AIR IMPACT WRENCH...

Page 2: ...nd accurate but all recommendations or suggestions are made without guarantee Since the conditions of use are beyond their control Jefferson Tools disclaim any liability for loss or damage suffered fr...

Page 3: ...hildren pets and animals away from the work area This equipment should only be used by trained and competent individuals who have read the user manual and fully understand how to operate the air impac...

Page 4: ...hing hands between tool and workpiece especially when unscrewing Be aware that the Tool and or accessories may briefly continue their motion after the trigger is released Keep others a safe distance f...

Page 5: ...d arms Keep the hands away from the sockets during operation If you experience numbness tingling pain or whitening of the skin in your fingers or hands stop using the assembly power tool for threaded...

Page 6: ...the compressor tools Ensure that the compressed air is cooled and its water content filtered and lubricated as required as shown in Fig 1 below Excessive moisture levels can be compressed in the pipe...

Page 7: ...with a forward rotation move the lever on the rear of the wrench to the F position To operate with a reverse motion move the lever to the R position This equipment is designed as a plug and run type d...

Page 8: ...alve Seat 1 6 Retainer Ring 1 26 Valve Stem 1 7 O Ring 1 27 Spring 1 8 Anvil 1 28 Exhaust Board 1 9 Hammer Pin 2 29 Filter 1 10 Hammer 2 30 Air Inlet 1 11 Hammer Frame 1 31 Reverse Valve Bushing 1 12...

Page 9: ...activate your warranty by visiting the Jefferson Tools website using the following address www jeffersontools com warranty and completing the online form Online warranty registration is recommended a...

Page 10: ...Jefferson cannot assume any responsibility for any damage incurred to equipment during transit Any claims against a third party courier will be dealt with under the terms conditions of their road haul...

Page 11: ...y INTERTEK TESTING CERTIFICATION LTD Intertek House Cleeve Road Leatherhead Surrey KT22 7SB Country United Kingdom Noise LpA 92 dB A KpA 3 dB A LwA 103 dB A KwA 3 dB A Vibration Uncertainty 5 47 m s K...

Page 12: ...ed Kingdom CH4 9QR Tel 44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating instructions o...

Reviews: